Skip to main content
. 2020 Apr 27;12(5):281. doi: 10.3390/toxins12050281

Table 6.

Dose-response curves parameters of CBA-N2a when detecting VGSC activators in fish samples.

Variability Sample ID Top Absorbance Bottom Absorbance EC80 *** (pg/µL) EC50 *** (pg/µL) Hillslope
Intra-assay * Cmic19 1.064 ± 0.007 0.001 ± 0.004 71.2 ± 8 130.6 ± 11 −2.282 ± 0.132
Emer05 1.110 ± 0.014 0.003 ± 0.004 114.7 ± 10 184.4 ± 10 −2.927 ± 0.271
Inter-assay ** Cmic19 1.084 ± 0.062 −0.003 ± 0.002 55.9 ± 12.1 109.5 ± 21.1 −2.056 ± 0.073
Emer05 1.081 ± 0.101 0.000 ± 0.002 102.2 ± 15.9 171.3 ± 20.5 −2.675 ± 0.196

* Data represent the mean ± SD of three microplates in one experiment (N2a cells at 810 P). ** Data represent the mean ± SD of one microplate in three independent experiments (N2a cells at 795, 797 and 798 P). *** OV+ conditions: 85.7/8.57 µM final concentrations.