Data on TLE procedure.

Parameter All Group With TEE Monitoring Without TEE Monitoring Mann–Whitney “U” Test/chi2 Test
Number of patients 3185 1079 2106
Number of extracted leads 5258 1760 3498
Oldest extracted lead (years); x ± SD 8.021
± 5.962
N = 3185
9.290
± 6.307
N = 1079
7.372
± 5.670
N = 2106
p < 0.001
Sum of dwell times of extracted leads (years); x ± SD 13.091
± 12.202
N = 3185
15.466
± 13.960
N = 1079
11.876
± 11.004
N = 2106
p < 0.001
Number of extracted leads in one patient; x ± SD 1.651
± 0.747
N = 3185
1.631
± 0.719
N = 1079
1.661
± 0.761
N = 2106
p = 0.477
HV therapy (ICD) lead was extracted; n (%) 874
(27.441)
N = 3185
341
(31.603)
N = 1079
533
(25.309)
N = 2106
p < 0.001
CS (LV pacing) lead was extracted; n (%) 417
(13.093)
N = 3185
122
(11.307)
N = 1079
295
(14.008)
N = 2106
p < 0.05
Extraction of abandoned lead(s) (any); n (%) 422
(13.250)
N = 3185
95
(8.804)
N = 1079
327
(15.527)
N = 2106
p < 0.001
Lead fracture during extraction; n (%) 137
(4.301)
N = 3185
51
(4.727)
N = 1079
86
(4.084)
N = 2106
p = 0.451
Loss of free lead fragment; n (%) 15
(0.471)
N = 3185
7
(0.648)
N = 1079
8
(0.380)
N = 2106
p = 0.438
Technical difficulty during TLE (any); n (%) 592
(18.587)
N = 3185
257
(23.818)
N = 1079
335
(15.907)
N = 2106
p < 0.001
Two or more technical difficulties; n (%) 127
(3.987)
N = 3185
75
(6.951)
N = 1079
52
(2.469)
N = 2106
p < 0.001
Necessity to change venous approach; n (%) 135
(4.240)
N = 3184
18
(1.668)
N = 1079
117
(5.558)
N = 2105
p < 0.001
Use of other than extracted lead venous approach; n (%) 173
(5.432)
N = 3185
28
(2.595)
N = 1079
145
(6.885)
N = 2106
p < 0.001
Necessity to use other than Byrd dilator tools (Evo, TightR, lassos, basket catheters); n (%) 183
(5.746)
N = 3185
75
(6.951)
N = 1079
108
(5.128)
N = 2106
p < 0.05
Procedure duration (skin-to-skin); minutes x ± SD 59.952
± 25.717
N = 3185
62.747
± 27.138
N = 1079
58.520
± 24.842
N = 2106
p < 0.001
Procedure duration (sheath-to-sheath time); minutes
x ± SD
15.125
± 23.274
N = 3185
15.374
± 24.396
N = 1079
14.997
± 22.682
N = 2106
p < 0.001
Procedure duration average single lead extraction time; minutes x ± SD 8.965
± 12.418
N = 3182
9.111
± 14.260
N = 1079
8.891
± 11.363
N = 2103
p < 0.01
Partial radiological success (retained tip or < 4 cm lead fragment); n (%) 136
(4.270)
N = 3185
34
(3.151)
N = 1079
102
(4.843)
N = 2106
p < 0.05
Complete clinical success; n (%) 3116
(97.834)
N = 3185
1056
(97.868)
N = 1079
2060
(97.816)
N = 2106
p = 0.975
Complete procedural success; n (%) 3064
(96.201)
N = 3185
1054
(97.683)
N = 1079
2010
(95.442)
N = 2106
p < 0.01
Procedure-related death (intra-, post-procedural); n (%) 6
(0.188)
N = 3185
0
(0.000)
N = 1079
6
(0.285)
N = 2106
p = 0.186
Died within 6 months; n (%) 166
5.212
N = 3185
48
(4.449)
N = 1079
118
(5.603)
N = 2106
p = 0.193
Died within one year; n (%) 263
(8.257)
N = 3185
83
(7.692)
N = 1079
180
(8.547)
N = 2106
p = 0.446

Abbreviations: coronary sinus (CV), left ventricle (LV), high voltage (HV), transvenous lead extraction (TLE). Mortality at 6 and 12 months after TLE was similar in both groups (Figure 1).