Skip to main content
. 2020 Mar 9;12:100257. doi: 10.1016/j.bonr.2020.100257

Fig. 2.

Fig. 2

a)-b) Percentage reduction of predicted structural properties (spring stiffness, K, and ultimate force, FU) caused by single lytic lesions simulated with different sizes (4%, 12%, 24%, and 35% of the VBvol) and different locations (C: centre, LR: lateral right, LL: lateral left, P: posterior, and A: anterior). c)-d) Percentage reduction of predicted structural properties (spring stiffness, K, and ultimate force, FU) caused by multiple lytic lesions simulated with different sizes (4%, 12%, and 24% of the VBvol) and different locations (P + A: posterior and anterior, P + LR: posterior and lateral right, P + LL: posterior and lateral left, LR + LL: lateral right and left, A + LR: anterior and lateral right, A + LL: anterior and lateral left).