Skip to main content
. 2020 Apr 1;361:112762. doi: 10.1016/j.cma.2019.112762

Table 2.1.

Parameters included in the sensitivity analysis, their ranges of values, units, (sub)model where they belong, the domain to which the corresponding (sub)model is applied to, and reference(s) from where the ranges of values are inferred.

Parameter Range of values Units (Sub)Model Applied to Ref.
kepi 0–1,000,000 Ba cm−1 Robin Ω0epi N/A
P0 7.5–30 mmHg Windkessel Ω0endo [24], [27]
Pej 33.75–135 mmHg Windkessel Ω0endo [24]
C 0.1–0.4 ml mmHg−1 Windkessel Ω0endo [27]
R 75–750 mmHg ms ml−1 Windkessel Ω0endo [27]
kort2 0.0–0.6 N/A Orthotropic activation Ω0 [40]
Tref 60–1200 kPa Active stress Ω0 [9]
ϕ 45–90 deg Fibre distribution Ω0 [50]
K 500–5000 kPa Passive stress Ω0 [27]
as 512.8–7692 Pa Passive stress Ω0 [27]