Skip to main content
. 2020 Jun 12;11:885. doi: 10.3389/fphar.2020.00885

Table 1.

Echocardiographic Analysis in wild type mice after Ang II infusion and PR-957 treatment.

Parameter Saline PR-957 Ang II AngII+PR-957
HR(bpm) 545 ± 3.5 538 ± 4.8 536 ± 6.7 544 ± 4.7
LV Mass(AW)(mg) 83.59 ± 3.86 84.45 ± 10.33 97.35 ± 6.36* 82.18 ± 4.46#
LVID;d(mm) 4.11 ± 0.08 4.08 ± 0.2 4.17 ± 0.04* 3.97 ± 0.1
LVID;s(mm) 2.64 ± 0.09 2.66 ± 0.15 2.37 ± 0.05* 2.75 ± 0.12
LVPW;d(mm) 0.68 ± 0.03 0.72 ± 0.03 0.98 ± 0.07* 0.65 ± 0.01#
LVPW;s(mm) 1.05 ± 0.04 1.05 ± 0.01 1.25 ± 0.08* 0.94 ± 0.05#
LVAW;d(mm) 0.63 ± 0.02 0.68 ± 0.03 0.81 ± 0.02* 0.61 ± 0.03#
LVAW;s(mm) 0.87 ± 0.02 0.85 ± 0.04 1.12 ± 0.05* 0.81 ± 0.04#
FS(%) 25.29 ± 0.22 26.33 ± 2.15 28.37 ± 3.31 24.55 ± 1.46

Values are mean ± SEM, n(%).

HR, heart rate; LV Mass, left ventricular mass; LVID, left ventricular internal diameter; LVPW, left ventricular posterior wall; LVAW, anterior left ventricular wall. *P < 0.05 vs Saline; #P < 0.05 vs Ang II.