Skip to main content
. 2020 Jun 12;11:885. doi: 10.3389/fphar.2020.00885

Table 2.

Echocardiographic Analysis in Ang II-infused mice after PR-957 and VO-Ohpic treatment.

Parameter Ang II AngII+PR-957 AngII+PR-957+VO-Ophpic
HR(bpm) 525 ± 12.5 544 ± 4.7 537 ± 15.8
LV Mass(AW)(mg) 108.7 ± 9.3 82.18 ± 4.46* 91.04 ± 3.51#
LVID;d(mm) 4.36 ± 0.13 4.17 ± 0.1 4.18 ± 0.05
LVID;s(mm) 3.2 ± 0.15 2.85 ± 0.12 2.94 ± 0.1
LVPW;d(mm) 0.85 ± 0.05 0.65 ± 0.01* 0.78 ± 0.01#
LVPW;s(mm) 1.15 ± 0.06 0.84 ± 0.05* 0.95 ± 0.03#
LVAW;d(mm) 0.86 ± 0.04 0.61 ± 0.03* 0.74 ± 0.03#
LVAW;s(mm) 1.11 ± 0.04 0.81 ± 0.04* 0.95 ± 0.04#
FS(%) 27.47 ± 4.11 24.54 ± 1.95 26.66 ± 1.87

Values are mean ± SEM, n(%).

HR, heart rate; LV Mass, left ventricular mass; LVID, left ventricular internal diameter; LVPD, left ventricular posterior wall; LVAW, anterior left ventricular wall. *P < 0.05 vs Saline; #P < 0.05 vs Ang II+PR-957.