Table 2.
Results of in-vitro tests: Mean, standard deviation, difference of the transferred linear momenta (∫F dt), and t-test statistical analysis of mean values of linear momenta transferred to tooth-PDL-mandible and dental implant-mandible constructs due to impact loading from release heights of 1, 2, and 3 cm.
Release height of impactor | 1 cm | 2 cm | 3 cm | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Subject | T-PDL-M | DI-M | Difference | p-value | T-PDL-M | DI-M | Difference | p-value | T-PDL-M | DI-M | Difference | p-value |
construct | construct | (%) | construct | construct | (%) | construct | construct | (%) | ||||
Linear Momentum (kg.m/s) | 2.92 ± 0.34 | 4.37 ± 0.8 | 33.1 | 0.03 | 3.69 ± 0.7 | 5.36 ± 1.13 | 31 | 0.06 | 4.80 ± 0.7 | 6.62 ± 0.93 | 27.5 | 0.027 |