Skip to main content
. 2020 Jun 19;16:203. doi: 10.1186/s12917-020-02399-z

Table 3.

The detection of the co-infection models by triplex real-time PCR

Co-infection proportion a Number of DNA copies (copies/μL) Co-infection real-time PCR Ct Value (mean ± SD) b
AIV NDV DTMUV AIV NDV DTMUV
AIV:NDV:DTMUV = 10:1:1 1 × 107 1 × 106 1 × 106 13.66 ± 0.13 18.15 ± 0.27 18.15 ± 0.27
AIV:NDV:DTMUV = 10:5:1 1 × 107 5 × 106 1 × 106 13.50 ± 0.28 17.25 ± 0.27 18.03 ± 0.16
AIV:NDV:DTMUV = 1:5:10 1 × 106 5 × 106 1 × 107 16.58 ± 0.22 17.13 ± 0.15 14.54 ± 0.28
AIV:NDV = 1:1 1 × 107 1 × 107 13.28 ± 0.48 14.43 ± 0.33
AIV:NDV = 10:1 1 × 107 1 × 106 13.57 ± 0.22 18.25 ± 0.23.
AIV:NDV = 100:1 1 × 107 1 × 105 13.93 ± 0.10 21.73 ± 0.38
AIV:DTMUV =1:1 1 × 107 1 × 107 13.43 ± 0.32 14.38 ± 0.34
AIV:DTMUV =10:1 1 × 107 1 × 106 13.57 ± 0.29 17.92 ± 0.32
AIV:DTMUV =100:1 1 × 107 1 × 105 13.24 ± 0.34 21.33 ± 0.18
NDV:DTMUV =1:1 1 × 107 1 × 107 14.32 ± 0.32 14.53 ± 0.22
NDV:DTMUV =10:1 1 × 107 1 × 106 14.49 ± 0.19 18.02 ± 0.14
NDV:DTMUV =100:1 1 × 107 1 × 105 14.54 ± 0.15 21.68 ± 0.23

a There were two kinds of co-infection models included:the triplex co-infection and duplex co-infection

b The data was shown as the mean ± SD (n = 3)

-: represents no design in the corresponding system