Skip to main content
. 2020 Jun 19;15:11. doi: 10.1186/s12263-020-00670-4

Table 2.

Overview of the validation criteria for candidate intake biomarkers for banana and tropical fruitsa

Food item Metabolites Biofluid Q1 Q2 Q3a Q3b Q4 Q5 Q6 Q7 Q8
Banana 5-Hydroxyindole acetic acid Plasma Y U Y U U U Y Y U
Banana 5-Hydroxyindole acetic acid Urine Y U Y U U U Y Y U
Banana 3-Methoxytyramine sulfate Plasma Y U U U Y U U U U
Banana Dopamine sulfate Plasma Y U Y U Y U Y Y U
Banana Dopamine sulfate Urine Y Y* Y U U U Y Y U
Banana Methoxyeugenol glucuronide Urine Y Y* Y U U U U U U
Banana Salsolinol sulfate Urine Y Y* Y U U U U Y U
Banana 6-OH-MTβC sulfate Urine Y Y* U U U U U U U
Banana Methoxyeugenol glucuronide + Dopamine sulfate Urine Y Y* Y U Y Y U U U
Banana Methoxyeugenol-glucuronide + Dopamine sulfate + Salsolinol sulfate Urine Y Y* Y U Y Y U U U
Banana Methoxyeugenol glucuronide + Dopamine sulfate + 6-OH-MTβC sulfate + 2-isopropylmalic acid Urine Y Y* Y U Y Y U U U
Banana Methoxyeugenol glucuronide + Dopamine sulfate + Salsolinol sulfate + Xanthurenic acid + 6-OH-MTβC sulfate Urine Y Y* Y U Y Y U U U
Avocado Perseitol Urine Y U Y* U U U U U U
Avocado Mannoheptulose Urine Y U Y* U U U U U U
Watermelon Citrulline Plasma Y U U U U U U U U
Watermelon Citrulline Urine Y U U U U U U U U

aQuestions related to each of the validation criteria: Q1. Is the marker compound plausible as a specific BFI for the food or food group (chemical/biological plausibility)?, Q2. Is there a dose-response relationship at relevant intake levels of the targeted food (quantitative aspect)?, Q3. Is the biomarkers kinetics described adequately to make a wise choice of sample type, frequency and time window (time-response) [a single-meal time-response relationship, b: repeated intakes have]?, Q4. Has the marker been shown to be robust after intake of complex meals reflecting dietary habits of the targeted population (robustness)?, Q5. Has the marker been shown to compare well with other markers or questionnaire data for the same food/food group (reliability)?, Q6. Is the marker chemically and biologically stable during bio specimen collection and storage, making measurements reliable and feasible (stability)?, Q7. Are analytical variability (CV %), accuracy, sensitivity, and specificity known as adequate for at least one reported analytical method (analytical performance)?, Q8. Has the analysis been successfully reproduced in another laboratory (reproducibility)?

Y yes the criterion is fulfilled, Y* the criterion is partially fulfilled but requires further investigation, N no the principle has not been fulfilled after investigation, U unknown; further data is required to determine the validation of the criterion, 6-OH-MTβC sulfate 6-hydroxy-1-methyl-1,2,3,4-tetrahydro-β-carboline sulfate