Table 2. Arrhenius Parameters (Pre-exponential Factor, A, and Activation Energy, Ea) Obtained from the Fitting Procedure for the Three Reaction Rate Coefficients.

  k1 k2 k3
A (min–1) 47 009 ± 37 108 129 ± 100 1344 ± 9
Ea (kJ mol–1) 40.8 ± 2.3 44.7 ± 2.8 40.8 ± 21.1