Table II.

Statistical results (mean ± standard deviation) for NiTi wire and SMA knitted actuators based on three repeated thermal cycles per fixed length (L1,2,3,…,n).

L1 L2 L3 L4 L5
70°C Flexinol Wire FA [N] 6.2 ± 0.1 6.6 ± 0.1 8.4 ± 0.1 10.8 ± 0.1 N.A.
FS [N] 1.9 ± 0.1 4.9 ± 0.1 9.5 ± 0.1 13.0 ± 0.1 N.A.
FM [N] 0.6 ± 0.1 5.3 ± 0.1 10.9 ± 0.1 14.8 ± 0.1 N.A.
NiTi #4 Wire FA [N] 0.0 ± 0.1 4.8 ± 0.4 4.8 ± 0.3 4.6 ± 0.1* N.A.
FPS [N] 0.3 ± 0.1 3.4 ± 0.1 3.8 ± 0.2 3.9 ± 0.1* N.A.
FM [N] 0.0 ± 0.0 0.1 ± 0.1 0.2 ± 0.1 3.6 ± 01* N.A.
70°C Flexinol
Knitted
Actuator
FA [N] 0.8 ± 0.1 1.0 ± 0.1 1.2 ± 0.1 1.7 ± 0.1 4.2 ± 1.1*
FS [N] 0.5 ± 0.1 0.8 ± 0.1 1.4 ± 0.1 2.5 ± 0.1* 5.3 ± 0.8*
FM [N] 0.0 ± 0.0 0.1 ± 0.0 0.3 ± 0.1 1.0 ± 0.1* No data*
NiTi #4
Knitted
Actuator
FA [N] 0.4 ± 0.1 0.6 ± 0.1 1.2 ± 0.1 1.8 ± 0.1 2.6 ± 0.6*
FPS [N] 0.3 ± 0.1 0.7 ± 0.1 1.6 ± 0.1 3.0 ± 0.1 4.9 ± 1.0*
FM [N] 0.0 ± 0.1 0.2 ± 0.1 0.6 ± 0.1 1.6 ± 0.2 4.1 ± 1.1*
*

Indicates less than 3 data points used due to equipment errors.