Skip to main content
. 2020 Jun 19;19:1533033820915710. doi: 10.1177/1533033820915710

Table 3.

Example of an Automatic Optimization Policy.

PTV MinDvh If TreatmentCourse.TotalDose.GetRelativeVolumeAtDoseValues (RoiName, DoseValues <0.95) plan.PlanOptimizations.Constraints.DoseFunctionParameters.PercentVolume = 96
Organ MaxDose If obj_fun.FunctionValue.FunctionValue <0.005,obj_fun.DoseFunctionParameters.DoseLevel = min(obj_fun.FunctionValue.PlanningValue * 0.95, obj_fun.DoseFunctionParameters.DoseLevel)
Control MaxEud If obj_fun.FunctionValue.FunctionValue <0.01,obj_fun.DoseFunctionParameters.DoseLevel = min(obj_fun.FunctionValue.PlanningValue * 0.92, obj_fun.DoseFunctionParameters.DoseLevel)

Abbreviations: obj_fun, plan.PlanOptimizations.Objective.ConstituentFunctions; PTV, planning target volume.