Table 3.
Example of an Automatic Optimization Policy.
PTV MinDvh | If TreatmentCourse.TotalDose.GetRelativeVolumeAtDoseValues (RoiName, DoseValues <0.95) plan.PlanOptimizations.Constraints.DoseFunctionParameters.PercentVolume = 96 |
Organ MaxDose | If obj_fun.FunctionValue.FunctionValue <0.005,obj_fun.DoseFunctionParameters.DoseLevel = min(obj_fun.FunctionValue.PlanningValue * 0.95, obj_fun.DoseFunctionParameters.DoseLevel) |
Control MaxEud | If obj_fun.FunctionValue.FunctionValue <0.01,obj_fun.DoseFunctionParameters.DoseLevel = min(obj_fun.FunctionValue.PlanningValue * 0.92, obj_fun.DoseFunctionParameters.DoseLevel) |
Abbreviations: obj_fun, plan.PlanOptimizations.Objective.ConstituentFunctions; PTV, planning target volume.