Skip to main content
. 2020 May 28;20(11):3065. doi: 10.3390/s20113065

Table 4.

Power loss for modified Emerson Electric and SMC motors for T = 0.35 Nm, n = 4400 rpm.

Type of Motor Input Power [W] Output Power [W] Copper Loss [W] Iron Loss [W]
Modified Emerson Electric 256 ± 1 161 ± 8 11.3 ± 0.8 83.7 ± 8.2
SMC 229 ± 1 161 ± 8 15.8 ± 1.1 52.2 ± 8.2