Table 3.
IAQ † | TC ‡ | VC § | AC ¶ | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer | Model | CO2 †† | CO ‡‡ | H2CO §§ | PM ¶¶ | VOC ††† | Temp | Air Velocity | RH ‡‡‡ | Lux | Light Colour | Sound |
SKC | AirChek 2000 [21] | - | - | - | - | - | - | √ | - | - | - | - |
Bruel and Kjaer | 1213 [4] | - | - | - | - | - | √ | √ | √ | - | - | - |
2250 [44] | - | - | - | - | - | - | - | - | - | - | √ | |
CO2Meters | CM-0018AA [45] | √ | - | - | - | - | √ | - | √ | - | - | - |
Extech | SD800 data logger [27] | √ | - | - | - | - | √ | - | √ | - | - | - |
EA80 data logger [22] | √ | - | - | - | - | √ | - | √ | - | - | - | |
Fieldpiece | SCM4 [20] | √ | - | - | - | - | - | - | - | - | - | - |
GrayWolf | FM-108 [23] | - | - | √ | - | - | √ | - | - | - | - | - |
IQ-410 [26] | √ | √ | - | - | √ | √ | - | √ | - | - | - | |
IQ-610 [23] | √ | √ | - | - | √ | √ | - | √ | - | - | - | |
PC-3016A [26] | - | - | - | √ | - | √ | - | √ | - | - | - | |
TG-502 [23,26] | - | - | - | - | √ | √ | - | √ | - | - | - | |
HalTech | HFX205 [20] | - | - | √ | - | - | √ | - | √ | - | - | - |
HOBO | U12-012 [43] | - | - | - | - | - | √ | - | √ | √ | - | - |
Konica Minolta | CL-500A [36] | - | - | - | - | - | - | - | - | √ | √ | - |
Lascar | EL-USB-CO [23] | √ | - | - | - | - | - | - | - | - | - | - |
Monnit Corp | Wireless Humidity Sensor [36] | - | - | - | - | - | - | - | √ | - | - | - |
Wireless Temp Sensor [36] | - | - | - | - | - | - | - | - | - | - | - | |
NTi Audio | XL2 Analyzer [36] | - | - | - | - | - | - | - | - | - | - | √ |
Rion | NL-52 [20] | - | - | - | - | - | - | - | - | - | - | √ |
Telaire | 7000 [43] | √ | - | - | - | - | - | - | - | - | - | - |
7001 [7,23] | √ | - | - | - | - | - | - | - | - | - | - | |
TSI | DustTrak II 8532 [20] | - | - | - | √ | - | - | - | - | - | - | - |
Q-Trak 7575 [20,34] | √ | √ | - | - | √ | √ | - | √ | - | - | - | |
Q-Trak 964 [36] | - | - | - | - | - | √ | √ | √ | - | - | - | |
SidePak AM510 [23] | - | - | - | - | √ | - | - | - | - | - | - | |
Velocicalc 9545 [45] | - | - | - | - | - | √ | √ | √ | - | - | - | |
Watson | N-8681 SOLAR [22] | - | - | - | - | - | √ | √ | √ | √ | - | - |
Wilks | InfraRan Specific Vapor Analyzer [45] | √ | √ | √ | - | - | - | - | - | - | - | - |
Wholër | CO2 datalogger [22] | √ | - | - | - | - | - | - | - | - | - | - |
Wovyn | Lux1000 | - | - | - | - | - | - | - | - | √ | - | - |
Wovyn | Color Lux1000 | - | - | - | - | - | - | - | - | √ | √ | - |
Table outlines state-of-the-art sensors used within reviewed studies, outlining the manufacturers, models and measurement, factors. These sensors cost range from several hundreds of pounds to several thousand. † Indoor Air Quality. ‡ Thermal Comfort. § Visual Comfort. ¶ Acoustic Comfort. †† Carbon Dioxide. ‡‡ Carbon Monoxide. §§ Formaldehyde. ¶¶ Particulate Matter (PM1.0/PM2.4/PM10). ††† Volatile Organic Compounds. ‡‡‡ Relative Humidity.