Skip to main content
. 2020 Jun 18;11:643. doi: 10.3389/fgene.2020.00643

TABLE 3.

Positive detection rates of ColoDefense test with different algorithm combinations for mSEPT9 and mSDC2 in detecting AA, CRC, and control.

Algorithm
Group Subject number (n) Positive detection rate (95% CI:%) Youden index (%)
mSEPT9 mSDC2
3/3 2/3 AA 6 83.3 (36.5–99.1) 54.1
CRC 55 94.5 (83.9–98.6) 65.3
Control 65 29.2 (18.9–42.0) N/A
3/3 3/3 AA 6 66.7 (24.1–94.0) 42.1
CRC 55 90.9 (3.4–20.7) 66.3
Control 65 24.6 (15.1–37.1) N/A
3/3 and mean Ct <40 2/3 AA 6 83.3 (36.5–99.1) 60.3
CRC 55 90.9 (3.4–20.7) 67.8
Control 65 23.1 (13.9–35.5) N/A
3/3 and mean Ct <40 3/3 AA 6 66.7 (24.1–94.0) 48.2
CRC 55 87.3 (74.9–94.3) 68.8
Control 65 18.5 (10.3–30.4) N/A
3/3 and mean Ct <39 2/3 AA 6 83.3 (36.5–99.1) 71.0
CRC 55 89.1 (77.1–95.5) 76.8
Control 65 12.3 (5.8–23.4) N/A
3/3 and mean Ct <39 3/3 AA 6 66.7 (24.1–94.0) 59.0
CRC 55 87.3 (74.9–94.3) 79.6
Control 65 7.7 (2.9–17.8) N/A
3/3 and mean Ct <38 2/3 AA 6 66.7 (24.1–94.0) 57.4
CRC 55 89.1 (77.1–95.5) 79.9
Control 65 9.2 (3.8–19.7) N/A
3/3 and mean Ct <38 3/3 AA 6 50.0 (13.9–86.1) 43.8
CRC 55 87.3 (74.9–94.3) 81.1
Control 65 6.2 (2.0–15.8) N/A

N/A, not applicable.