Skip to main content
. 2020 Jun 26;20:308. doi: 10.1186/s12872-020-01584-0

Table 2.

Angiographic and procedural characteristics

Parameters Intracoronary prourokinase group (N = 25) Control group (N = 25) P value
Infarction related artery, No. (%) 0.829
 LAD 8 (32.0) 10 (40.0)
 LCX 3 (12.0) 3 (12.0)
 RCA 14 (56.0) 12 (48.0)
No. of diseased vessels, No. (%) 0.776
 1 4 (16.0) 3 (12.0)
 2 5 (20.0) 7 (28.0)
 3 16 (64.0) 15 (60.0)
Thrombus grade before PCI, No. (%) 0.750
 1 4 (16.0) 0 (0.0)
 2 0 (0.0) 1 (4.0)
 3 0 (0.0) 3 (12.0)
 4 2 (8.0) 4 (16.0)
 5 19 (76.0) 17 (68.0)
Collateral vessel, No. (%) 15 (60.0) 17 (68.0) 0.556
Temporary pacemaker, No. (%) 2 (8.0) 3 (12.0) 0.637
Number of stents, mean ± SD 1.12 ± 0.33 1.08 ± 0.28 0.646
Stent diameter, mean ± SD, mm 3.01 ± 0.51 3.09 ± 0.55 0.590
Stent length, mean ± SD, mm 23.48 ± 4.49 22.84 ± 6.57 0.690
Stent release pressure, mean ± SD, atm 14.12 ± 3.59 12.72 ± 4.34 0.220
Number of inflations, mean ± SD 3.96 ± 1.54 4.79 ± 2.23 0.134
Pre-dilation pressure, mean ± SD, atm 12.16 ± 3.05 11.48 ± 2.69 0.408
Post dilation, No.(%) 15 (60) 13 (52) 0.569
Post-dilation times, median (IQR) 3 (1–4) 3 (2–5) 0.918
Trans-radial or ulnar artery, No.(%) 25 (100.0) 25 (100.0) 1.000

Differences between two groups were determined by Student’s t-test, Mann-Whitney U test, Chi-squared test or Fisher’s exact test, as appropriate. FMC first medical contact, LAD left anterior descending, LCX left anterior descending, RCA right coronary artery, PCI percutaneous coronary intervention, SD standard deviation, IQR interquartile range