Table 1.

The air cleaning factor (ACF) provided by continuous operation of the ion emitter: (a) VI-2500 and (b) AS150 mm (+)/(−)

Aerodynamic particle diameter (μm) Air cleaning factor
15 min 30 min
(a) VI-2500
0.04 5.2±2.6 15.3±2.6
0.1 6.8±0.7 31.0±2.0
0.2 6.7±0.5 33.6±5.5
0.5 5.7±1.1 25.8±7.3
1 5.0±1.1 18.7±3.6
2 5.3±1.7 22.1±5.1
Aerodynamic particle diameter (μm) Air cleaning factor
15 min
30 min
60 min
AS150MM (+) AS150MM (−) AS150MM (+) AS150MM (−) AS150MM (+) AS150MM (−)
(b) A5150MM(+)/(−)
0.04 1.4 ± 0.3 1.2 ± 0.2 2.1 ± 0.4 1.8 ± 0.2 3.9 ± 0.8 3.9 ± 0.2
0.1 1.9 ± 0.3 1.7 ± 0.2 2.9 ± 0.6 2.7 ± 0.3 5.9 ± 1.3 6.4 ± 0.5
0.2 1.5 ± 0.1 1.4 ± 0.1 2.3 ± 0.4 2.3 ± 0.2 5.4 ± 1.4 6.2 ± 0.4
0.5 1.9 ± 0.9 2.3 ± 1.1 2.9 ± 1.4 3.4 ± 1.6 5.5 ± 2.2 7.2 ± 2.8
1 1.9 ± 0.6 2.2 ± 1.0 2.6 ± 0.8 3.1 ± 1.2 4.7 ± 1.0 5.9 ± 1.9
2 2.3 ± 0.7 2.4 ± 0.9 3.0 ± 1.0 3.2 ± 1.1 4.7 ± 1.1 5.6 ± 1.6