Skip to main content
. 2004 Aug 12;38(29):4815–4823. doi: 10.1016/j.atmosenv.2004.06.010

Table 2.

The electrical mobility calculated from the particle charge distribution measurement data

Aerodynamic particle diameter (μm) Electrical mobility (m2 V−1 s-1)
VI-2500 AS150MM (+) AS150MM (−)
0.04 −2.5×10−7 1.5×10−7 −1.8×10−7
0.1 −2.6×10−7 1.9×10−7 −1.9×10−7
0.2 −2.3×10−7 1.6×10−7 −1.7×10−7
0.5 −2.3×10−7 1.5×10−7 −1.6×10−7
1 −2.6×10−7 1.6×10−7 −1.7×10−7
2 −3.3×10−7 2.0×10−7 −2.2×10−7