Table 1.
Drying durations by dose and product: value of percentile 25 of duration of tests made for each product and each duration (i.e. 75% of tests have been longer than this value).
| EN 1500 contact time validateda | Products | Dose 1.5 ml | Dose 2 ml | Dose 3 ml | |||
|---|---|---|---|---|---|---|---|
| Tests number | Percentile 25b (s) | Tests number | Percentile 25b (s) | Tests number | Percentile 25b (s) | ||
| 15 s | Purell | 28 | 21 | 33 | 30 | 28 | 41 |
| Purell 85 | 14 | 20 | 21 | 24 | 14 | 32 | |
| Softalind hand sanitizer | 14 | 19 | 14 | 25 | 14 | 28 | |
| 30 s | Actisène alcoogel | 25 | 26 | 14 | 25 | 30 | 44 |
| Alcocide | 19 | 24 | 19 | 25 | 19 | 40 | |
| Alcogel H | 24 | 19 | 24 | 22 | 24 | 35 | |
| Anios gel 85 NPC | 22 | 22 | 26 | 25 | 29 | 35 | |
| Dermalkan | 14 | 25 | – | – | – | – | |
| Desderman gel | 41 | 19 | 28 | 25 | 42 | 40 | |
| Desderman N | 32 | 17 | 30 | 25 | 34 | 32 | |
| Elusept gel | 11 | 25 | 13 | 25 | 11 | 30 | |
| GHA | 12 | 25 | 11 | 35 | 12 | 56 | |
| Manugel 85 NPC | 21 | 20 | 31 | 25 | 21 | 33 | |
| Manupure | 14 | 28 | – | – | 14 | 37 | |
| Manurub | 18 | 25 | 17 | 31 | 19 | 47 | |
| Manurub gel | 19 | 20 | 7 | 28 | 27 | 43 | |
| Nosocomia gel | 19 | 22 | 19 | 25 | 19 | 31 | |
| Spitacid | 14 | 20 | 14 | 22 | 14 | 30 | |
| Spirigel | 28 | 17 | 28 | 25 | 28 | 31 | |
| Sterilium | – | – | 15 | 30 | – | – | |
| Alco Aloe gel | 26 | 21 | 33 | 28 | 26 | 42 | |
| Alco Aloe solution | 27 | 19 | 14 | 19 | 25 | 21 | |
| 2 × 30 s | Assanis pro | 21 | 22 | 21 | 24 | 21 | 37 |
| Elusept solution | 25 | 18 | 19 | 20 | 26 | 30 | |
| Procide | 14 | 22 | 14 | 25 | 15 | 38 | |
| Septigel | 36 | 20 | 24 | 26 | 34 | 36 | |
| Stoko progel | 17 | 22 | 20 | 24 | 14 | 39 | |
| Stokosept | 20 | 25 | 24 | 31 | 32 | 41 | |
Suppliers data.
Value of percentile 25: the duration of hand rubbing was considered effective, according to the 2002 French guidelines, if this value is longer than or equal to 30 s, and effective according to the EN 1500 if this value is longer than or equal to that of the contact time validated by the product by means of EN 1500.