Table 1.

Tested filter materials.

Material Surgical face mask Hygienic mask Toilet paper Paper towel Coffee filter
Pressure drop at 60 l/min [mbar] 0.2 a 0.3 0.3 1.8
Pressure drop at 90 l/min [mbar] 0.4 a 0.6 0.7 4.0



Material
Microfibre cloth
Fleece
Vacuum cleaner bag
FFP3 mask with valve
Halyard H600
Pressure drop at 60 l/min [mbar] 7.7 0.1 2.0 b 1.4
Pressure drop at 90 l/min [mbar] 17.2 0.2 4.5 b 3.1
a

Not measured.

b

Not available. Due to the valve and the resulting inhomogeneous flow field, the volume flow rate could not be determined with the method applied.