Skip to main content
. 2020 May 28;13(11):2452. doi: 10.3390/ma13112452

Table 2.

Results of hard body impact resistance test, according to ETAG 004/2013 [16].

Set Number Tests Results after
Impact 3 Joule Impact 10 Joule
Set I no deterioration of 5 tested samples
  • Cavity without deterioration of 1 tested sample;

  • circular deterioration of 3 tested samples, diameters: 3.6 mm, 4.0 mm, 3.1 mm,

  • one crack length of 1 cm

Set II no deterioration of 5 tested samples no deterioration of 5 tested samples
Set III no deterioration of 5 tested samples
  • Cavity without deterioration of 2 tested samples;

  • circular deterioration of 3 tested samples about diameters: 3.1 mm, 3.2 mm and 3.5 mm

Set IV no deterioration of 5 tested samples
  • Cavity without deterioration of 3 tested samples;

  • circular deterioration of 2 tested samples about diameters: 3.1 mm, and 3.6 mm