Skip to main content
. 2020 Jun 19;2020:7625725. doi: 10.1155/2020/7625725

Table 4.

Summary of previous studies on the predictability of intraocular lens power calculation in eyes with steep and flat corneas.

Author Number of eyes Mean keratometric readings (D) IOL calculation formula Prediction error (D) Within ± 0.5 D (%) Within ± 1.0 D (%)
Faramarzi et al [9] 45 46≦ SRK/T −0.06 ± 0.52 78 89
Holladay1 0.21 ± 0.51 64 96
Haigis 0.16 ± 0.55 64 93
Hoffer Q 0.36 ± 0.51 58 91

Reitblat et al [10] 79 46< Barrett Universal II −0.04 ± 0.45 76 96
SRK/T −0.31 ± 0.54 61 91
Hill-RBF −0.17 ± 0.35 83 98
Hoffer Q 0.18 ± 0.57 70 92
Holladay1 −0.06 ± 0.52 70 94
Holladay2 −0.04 ± 0.51 73 96
Olsen-A 0.07 ± 0.41 78 99
Olsen-C 0.18 ± 0.41 68 99
Haigis 0.17 ± 0.42 71 97
92 <42 Barrett Universal II −0.07 ± 0.26 97 100
SRK/T 0.16 ± 0.31 86 100
Hill-RBF −0.14 ± 0.26 88 100
Hoffer Q −0.22 ± 0.68 80 96
Holladay1 0.04 ± 0.39 83 99
Holladay2 −0.02 ± 0.35 86 99
Olsen-A −0.06 ± 0.31 91 98
Olsen-C −0.17 ± 0.33 90 99
Haigis −0.31 ± 0.31 75 97

Current 86 47≦ Barrett Universal II 0.08 ± 0.49 71 97
SRK/T −0.49 ± 0.63 60 84
69 <42 Barrett Universal II 0.15 ± 0.42 74 96
SRK/T 0.27 ± 0.40 70 94