. 2020 Jun 29;24:382. doi: 10.1186/s13054-020-03092-1

Table 5.

Microbial isolation from positive endotracheal tube tip cultures

Organism PVC tube (n = 14) SC tube (n = 13) NbMC tube (n = 22) All tubes (n = 49)
Gram-positive bacteria
Staphylococcus aureus 2 (11) 2 (13) 1 (3.7) 5 (8.2)
Enterococcus faecalis 3 (16) 2 (7.4) 5 (8.2)
Enterococcus faecium 1 (5.6) 1 (6.2) 2 (3.3)
Staphylococcus epidermidis 1 (6.3) 1 (1.6)
Gram-negative bacteria
Pseudomonas aeruginosa 1 (5.6) 3 (11) 4 (6.6)
Stenotrophomonas maltophilia 4 (15) 4 (6.6)
Klebsiella species 1 (6.2) 1 (3.7) 2 (3.3)
Chryseobacterium indologenes 2 (7.4) 2 (3.3)
Escherichia coli 1 (6.2) 1 (1.6)
Serratia marcescens 1 (5.6) 1 (1.6)
Acinetobacter species 1 (6.2) 1 (1.6)
Citrobacter freundii 1 (3.7) 1 (1.6)
Yeast
Candida spp. 9 (50) 9 (56) 13 (48) 31 (51)
Candida albicans 8 (44) 7 (44) 9 (33) 24 (39)
 Other yeasts 1 (5.6) 1 (1.6)
Total number of microorganisms cultured from ETTs 18 (100) 16 (100) 27 (100) 61 (100)

Data are presented as number (percentage). Approximately 20% of all endotracheal tube tips were polymicrobial. Abbreviations: PVC polyvinyl-chloride, SC silicone-coated, NbMC noble-metal-coated