Table 1. Results of testing for SARS-CoV-2 in intensive care unit, Huoshenshan Hospital, Wuhan, China, 2020*.
Area, sample |
Intense positive/weak positive/negative† |
Rate of positivity, % |
Average virus concentration‡ |
---|---|---|---|
Contaminated area | |||
Isolation wards | |||
Floor | 6/1/3 | 70 | 6.6 × 104 |
Computer mouse | 4/2/2 | 75 | 2.8 × 104 |
Trash can | 0/3/2 | 60 | 3.4 × 104 |
Sickbed handrail | 2/4/8 | 42.9 | 4.3 × 104 |
Patient mask | 1/1/3 | 40 | 3.3 × 103 |
Air outlet filter | 4/4/4 | 66.7 | 1.5 × 105 |
Indoor air near the air outlet (sampling site 1 in Figure 2, panel A) | 2/3/9 | 35.7 | 3.8 |
Indoor air near the patients (sampling site 2 in Figure 2, panel A) | 2/6/10 | 44.4 | 1.4 |
Indoor air near the doctors’ office area (sampling site 3 in Figure 2, panel A) | 0/1/7 | 12.5 | 0.52 |
Pharmacy | |||
Floor | 3/0/0 | 100 | 7.45 × 104 |
Indoor air | 0/0/5 | 0 | ND |
PPE | |||
Face shield of medical staff | 0/0/6 | 0 | ND |
Sleeve cuff of medical staff | 0/1/5 | 16.7 | 7.1 × 103 |
Glove of medical staff | 0/1/3 | 25 | 2.9 × 103 |
Shoe sole of medical staff | 3/0/3 | 50 | 3.2 × 104 |
Subtotal |
27/27/70 |
43.5 |
NA |
Semicontaminated area | |||
Buffer room 1 | |||
Floor | 0/0/5 | 0 | ND |
Air outlet filter | 0/0/3 | 0 | ND |
Indoor air | 0/0/5 | 0 | ND |
Doorknob | 0/0/3 | 0 | ND |
Dressing room 4 | |||
Floor | 0/3/5 | 37.5 | 3.8 × 103 |
Air outlet filter | 0/0/3 | 0 | ND |
Indoor air | 0/0/5 | 0 | ND |
Doorknob | 0/0/4 | 0 | ND |
Subtotal |
0/3/33 |
8.3 |
NA |
Clean area | |||
Dressing rooms 1, 2, and 3 | |||
Doorknob | 0/0/10 | 0 | ND |
Floor | 0/0/12 | 0 | ND |
Indoor air | 0/0/8 | 0 | ND |
Nurse station | |||
Doorknob | 0/0/5 | 0 | ND |
Floor | 0/0/5 | 0 | ND |
Indoor air | 0/0/5 | 0 | ND |
Dressing rooms 5 and 6, buffer rooms 2 and 3 | |||
Doorknob | 0/0/12 | 0 | ND |
Floor | 0/0/12 | 0 | ND |
Indoor air | 0/0/12 | 0 | ND |
Subtotal |
|
|
|
Total | 27/30/184 | 23.7 | NA |
*NA, not applicable; ND, not determined; PPE, personal protective equipment; SARS-CoV-2, severe acute respiratory syndrome coronavirus 2. †Intense positive indicates a positive result for both open reading frame 1ab gene and nucleoprotein gene of SARS-CoV-2; weak positive indicates a positive result for only 1 of the genes. ‡The average virus concentration of indoor air expressed as copies/L and of swab samples, as copies/sample.