Table 4. Correlations between ODs/OD ratios and PRNT results of 31 serum samples from 9 PCR-confirmed COVID-19 patients tested from Germany and tested in in Berlin, Germany, 3–23 d after disease onset*.
| Test, virus | Correlation | Euroimmun ELISAs |
|
|---|---|---|---|
| IgA | IgG | ||
| PRNT50, SARS-CoV-2 |
Spearman ρ value | 0.63 | 0.5077 |
| 2-tailed p value | 0.056 | 0.1368 | |
| p value summary |
NS |
NS |
|
| PRNT90, SARS-CoV-2 | Spearman ρ value | 0.7922 | 0.8525 |
| 2-tailed p value | 0.0004 | <0.0001 | |
| p value summary | <0.001 | <0.0001 | |
*COVID-19, coronavirus disease 2019; NS, not significant; OD, optical density; PRNT50, 50% plaque reduction neutralization test; PRNT90, 90% plaque reduction neutralization test; SARS-CoV-2, severe acute respiratory syndrome coronavirus 2.