Skip to main content
. Author manuscript; available in PMC: 2021 Apr 1.
Published in final edited form as: J Appl Microbiol. 2019 Dec 12;128(4):1050–1059. doi: 10.1111/jam.14532

Table 3.

Venezuelan equine encephalitis virus (IAB and TC83), time to nondetect, recovery and Di

Test organism Target environmental conditions Material Time (h) Control recovery (log10 PFU)* Test recovery (log10 PFU)* Control Di (h) Test Di (h)
VEEV IAB 58·3 ± 10·7°C Glass 12 6·6 0·0 39·3 1·6
29·2 ± 10·5% RH Paper 12 5·8 0·0 23·9 1·7
VEEV TC83 Glass 12 6·1 0·0 31·2 1·6
Paper 6 1·6 0·0 29·3 3·1
VEEV IAB 37·7 ± 0·6°C Glass 24 6·9 0·0 35·2 3·1
75·7 ± 2·5% RH Paper 24 6·2 0·0 28·6 3·2
VEEV TC83 Glass 24 6·3 0·0 39·2 3·2
Paper 24 0·9 0·0 23·8 5·5
VEEV IAB 38·1 ± 2·1°C Glass 96 4·8 0·0 31·5 12·2
41·4 ± 5·6% RH Paper 96 4·4 1·3 29·5 15·1
VEEV TC83 Glass 96 5·3 1·2 41·0 14·9
Paper 12 2·8 0·0 22·1 2·8
VEEV IAB 21·8 T 0·3°C Glass 96 5·9 3·2 53·3 21·5
74·7 T 3·6% RH Paper 96 6·2 0·0 64·4 12·6
VEEV TC83 Glass 96 4·9 3·3 43·1 24·9
Paper 24 2·15 0·0 37·5 6·5
*

Total log10 value remaining at longest timepoint or at first instance of nondetect, theoretical limit of detection 33 PFU.

Incomplete inactivation at longest timepoint tested.