Skip to main content
. 2020 Jul 1;284:113924. doi: 10.1016/j.jviromet.2020.113924

Fig. 5.

Fig. 5

Comparison between samples of genomic DNA and serum for the LAMP assay.

M: DL2000 DNA marker; Lane 1, 2 and 3: LAMP reactions were carried out with 3 samples of serum, respectively; Lane 4, 5 and 6: LAMP reactions were carried out with genomic DNA of the same 3 samples, rspectively; Lane 7: positive control; Lane 8: no template control.

All reactions were carried out at 59.0 ℃ for 50 min and terminated at 80 ℃ for 3 min. The concentration of genomic DNA templates of serum samples is 10 ng per μL. Plasmids containing PPV VP1 gene fragment with the concentration 104 copies per μL were as positive control.

Upper: Results on 2 % (w/v) agarose gel electrophoresis staining with Goldview.

Lower: Visual results by adding SYBR Green I.