Table 7. Pre and post transcatheter aortic valve implantation right ventricular systolic pressure analyzed by baseline tricuspid regurgitation severity.

Variable Tricuspid regurgitation severity
None/mild (0–1+) (N=59) Moderate (2+) (N=26) Severe (3–4+) (N=9)
Pre-TAVR RVSP 37.5 (10.8) 55.7 (14.5) 61.6 (16.1)
Post-TAVR RVSP 39.2 (11.3) 44.6 (13.2) 47.2 (17.2)
P value 0.326 <0.001 0.072

Ninety-four patients had available pre and post TAVR RVSP. Variables presented as mean (standard deviation). RVSP, right ventricular systolic pressure; TAVR, transcatheter aortic valve implantation.