Skip to main content
. 2020 Mar 12;35(8):1135–1147. doi: 10.1007/s00380-020-01577-1

Fig. 3.

Fig. 3

Patient-specific model of the failing heart. a Time-lapse images showing propagation of activation (color) and contraction. The numbers indicate the time after the onset of activation. b Actual (left column) and simulated (right column) ECG c Pressure–volume loop of the left ventricle (upper panel) and dP/dt (lower panel)