Skip to main content
. 2020 Jul 2;4(3):036104. doi: 10.1063/5.0002750

TABLE I.

Averaged values of the elastic and viscous moduli measured at 1 rad/s as a function of the content of acrylamide, bis-acrylamide, and linear PAA in the initial gel mix. n = 5 gels.

G′ (Pa) G″ (Pa) % acrylamide % bis-acrylamide % of linear acrylamide
1636 1 4.5 0.1 0
1590 206 5.5 0.1 2.75
5580 10 8 0.1 0
6280 490 8 0.15 2.75