Table 5. Tissue Doppler imaging characteristics of in sevoflurane and sevoflurane + TAPB and RSB groups with diastolic dysfunction undergoing noncardiac surgery.
T1 | T2 | Pgroup×times | |
---|---|---|---|
e, cm.s−1 | 0.386 | ||
sev | 5.13 ± 1.30 | 5.71 ± 1.31 | |
sev + TAPB + RSB | 5.31 ± 1.49 | 6.25 ± 2.25 | |
a**, cm.s−1 | 0.009 <0.01 | ||
sev | 6.31 ± 1.68 | 7.12 ± 1.67 | |
sev + TAPB + RSB | 5.58 ± 1.72 | 5.45 ± 1.48 | |
e/a** | 0.005 <0.01 | ||
sev | 0.77 ± 0.33 | 0.85 ± 0.30 | |
sev + TAPB + RSB | 1.03 ± 0.35 | 1.19 ± 0.43 | |
E/e | 0.989 | ||
sev | 15.19 ± 6.06 | 14.25 ± 6.42 | |
sev + TAPB + RSB | 15.55 ± 7.45 | 13.85 ± 5.85 |
Notes.
- Sev
- sevoflurane
- TAPB + RSB
- transversus abdominis plane block and rectus sheath block
- e
- mitral lateral annulus movement in early diastole
- a
- mitral lateral annulus movementin in late diastole
- T1
- immediately after anesthesia induction hemodynamic stability as a baseline
- T2
- 1 hour after T1
Represent p < 0.01 between the two groups (linear mixed model).