Skip to main content
Saudi Pharmaceutical Journal : SPJ logoLink to Saudi Pharmaceutical Journal : SPJ
. 2020 May 29;28(7):779–790. doi: 10.1016/j.jsps.2020.05.006

Evaluation of heavy metals in cosmetic products and their health risk assessment

Hamna Arshad a, Moniba Zahid Mehmood a, Munir Hussain Shah b, Arshad Mehmood Abbasi a,
PMCID: PMC7335825  PMID: 32647479

Abstract

Heavy metals’ contamination in cosmetic products is a serious threat. Present study was conducted to evaluate the concentrations of heavy metals (HMs) in various brands of cosmetic products with special emphasis on their health risk assessment. Five heavy metals including Cd, Cr, Fe, Ni and Pb were quantified in different brands of lotions, foundations, whitening creams, lipsticks, hair dyes and sunblock creams using atomic absorption spectrometry. Risk to the consumer’s health was determined using systemic exposure dosage (SED), margin of safety (MoS), hazard quotient (HQ), hazard index (HI) and lifetime cancer risk (LCR).

On comparative basis, different brands of sunblock creams depicted highest concentration of Ni, Pb and Cr (7.99 ± 0.36, 6.37 ± 0.05 and 0.43 ± 0.01 mg/kg, respectively), whereas lipsticks had elevated levels of Fe at 12.0 ± 1.8 mg/kg, and Cd was maximum in lotions (0.26 ± 0.02 mg/kg). Multivariate analysis revealed strong associations among Cr, Ni and Pb, while Cd and Fe showed disparity in distribution and sources of contamination. MoS, HQ and HI values were within the permissible limit apart from for lotions and sunblock creams, while LCR value was higher than the permissible limit in all cosmetic products except lipsticks. Regular use of these products can cause serious threat to human health, particularly skin cancer on long time exposure. Therefore, continuous monitoring of cosmetic products, particularly with reference to HMs adulteration should be adopted to ensure the human safety and security.

Keywords: Heavy metal, Cosmetics, Health risk, MoS, HQ, HI, LCR, Pakistan

1. Introduction

Application of different cosmetics for personal care is as old as human civilization. With the passage of time, demand of cosmetics has increased many folds throughout the world. This is mainly owing to the increased awareness about methods to enhance the outlook of the body (Ullah et al., 2017). Today the use of cosmetics for personal grooming and body care has become the norm throughout the world (OJEU, 2009). The global market for beauty products has shown an average increase of about 5% per year. It is an interesting fact that the market for cosmetics and personal care products has shown constant and stable growth ever since its origin and has progressed even in unstable economies (Barbalova, 2011).

Cosmetic products are composed of different organic and inorganic materials including hydrophilic and hydrophobic substances. In the manufacturing of coloured cosmetics, mineral pigments are commonly used which leads to the contamination of cosmetic products with heavy metals (HMs) such as, Cu, Ni, Co, Pb, Cr, Cd and other elements. These HMs become a part of cosmetic product intentionally in the form of pigments, preservatives, UV filters as well as antiperspirant, antifungal and antibacterial agents (Burger et al., 2016). It has been reported that human exposure to UV radiations can cause chronic as well as acute health effects on human skin, eye and immune system. Thus, cosmetic manufacturers use UV filters as important ingredients in sunscreens and other daily used cosmetic products. Though, UV filters are designed for the cosmetic products that are intended to apply on topical skin surface but derivatives of the products can bind to plasma protein and get circulated in the blood, then through phase I and II biotransformation reaction that get metabolized in the liver. Afterwards they may either be excreted through urine or they can be bio-accumulated within the organism (Locatelli et al., 2019). Some metals as well as parabens are incorporated as preservatives in cosmetic products because they possess antibacterial and antifungal properties. Through recent studies it has been evaluated that metals and parabens used as preservatives are also endocrine disruptors and can get easily absorbed through skin thus causing adverse effects on human health (Tartaglia et al., 2019, Iavicoli et al., 2009). Some metallic compounds are routinely used in the cosmetics as they possess properties to peel and whiten the skin (Burger et al., 2016). However, use of metals components are based on regulatory laws of a particular country (OJEU, 2009). Heavy metals are also added accidently as impurities at various stages of cosmetic production. As the sort of raw material used in the manufacturing process, particularly the addition of additives and colour minerals cause contamination. In addition, water used for their preparation may also contain metallic impurities. Moreover, use of different instrumentation in cosmetic industries during sorting, manufacturing and packaging processes may also cause HMs contamination (Łodyga Chruścińska et al., 2018).

Trace quantities of some toxic metals (such as Cd and Pb) have been found in many products including toothpastes, face make-up and lipsticks etc. (Li et al., 2015). It has also been reported that natural ingredients like plant based materials are the major source of heavy metal contamination in cosmetics (Bocca et al., 2014). It has been recommended by The International Organizations to measure the quantity of toxic metals in the plants used as raw material as well as in the final products. As previously reported that toxic metals may be present in herbs and plants as a result of pre-existing use of fertilizers, insecticides or due to their cultivation near industrial zones. Therefore principal analytical procedures should be followed to reduce heavy metal concentration in raw material and to ensure the quality of final products (Locatelli et al., 2014).

In past it was assumed that the cosmetics are only associated with local effects but in the last few decades concerns were raised after the fact that certain substances in cosmetics may penetrate deep into the skin and get exposed to the organs. This stirred skin tests to check the penetration/adsorption capability of certain substances from the products as well as their toxicity (Nohynek et al., 2010). Although the outer most protective layer of skin (stratum corneum) does not allow large penetration, traces of HMs present in cosmetic products may reach the circulatory system (Bocca et al., 2014). Some of the metals have tendency to get accumulated with stratum corneum and cause allergic effects while others are diffusible in sweating, tears and sebum excretion and may penetrate through the skin appendages or through trans-cellular and intracellular pathways and reach blood circulatory system of human body. Therefore, daily application of many cosmetic products may results in increasing exposure of HMs to human body (Brzóska et al., 2018).

Elevated exposure to the heavy metals may result in numerous health problems including skin allergies, severe redness, swelling/skin ulcers, cellular death, DNA damage, oxidative stress, neurotoxicity, memory loss, reproductive failure and carcinogenic health effects (Kim et al., 2015, Bocca et al., 2014, Senesse et al., 2004, Agoramoorthy et al., 2008, Al Amry et al., 2011, Smith et al., 2015). In this context, the present study was focused on the determination of heavy metal concentrations in selected cosmetic products and to appraise health risks associated with exposure to the metals in cosmetic products. It is anticipated that the present study would provide pivotal information related to the health risks associated with the prolonged use of the cosmetic products.

2. Material and methods

2.1. Sample collection

Most commonly used cosmetic products (more than 70% frequency) were considered and collected for analysis in the present study. The usage frequency was calculated based on the data extracted from the questioner filled by more than 100 users during this study. It was ensured that the selected samples were representatives of most available, popular and commonly used product types. Locally manufactured and imported cosmetic products (n = 189) were collected in triplicates from local community and markets of Abbottabad, Haripur and Mansehra, Pakistan. The cosmetic products were sampled into six different groups; lotions (30 brands), foundations (9 brands), whitening creams, lipsticks, hair dyes and sunblock (6 brands each). Samples were stored at room temperature before analysis.

2.2. Washing

Washing is the most critical step for accurate heavy metal analysis. Washing of all accessories was done following the protocol of Olmedo et al. (2010). All glassware were washed first with detergent and then rinsed repeatedly with tap water. Afterwards, glassware were soaked in a solution of HNO3 (5%) for about 24 h. Then rinsing was done using deionised water and dried at 80 °C for 48 h before use.

2.3. Sample preparation

The collected samples were digested using acids mixture (HNO3, H2SO4 and HClO4 in ratio of 1:1:1) following the procedure reported by Saeed et al., 2011, Ayenimo et al., 2010 with modifications. Approximately, 1.0 g of each sample (in triplicate) was taken in 50 mL conical flask, followed by the addition of 5 mL of HNO3 and the mixture was kept overnight at room temperature. Subsequently, the contents were heated on a hot plate by slowly increasing the temperature up to 90 °C and after appearance of brown fumes, mixture was allowed to cool. Then H2SO4 (5 mL) was added and heated again for 30–60 min followed by cooling to room temperature. Finally, then 5 mL of HClO4 was added and the contents were digested until clear solution was obtained. After digestion, the samples were cooled to room temperature and filtered through Whatman filter paper No. 41 and the final volume (50 mL) was adjusted by deionised water. Blanks were also prepared following the same procedure with each batch of samples (n = 5). All the digested samples were stored in refrigerator till further analysis.

2.4. Quantification of HMs

Quantification of selected metals was done using atomic absorption spectrophotometer (Perkin Elmer AAnalyst 700) at their specific wavelength. Calibration line method was employed under optimum analytical conditions (Table S1) for the analysis of selected HMs. Standard stock solutions (1000 mg/L) of the metals were used to prepare the working standards freshly on the day of analysis. Countercheck of the results was ensured through the internal standard analysis as well as by standard reference materials (NIST SRM 1515) which showed very good recovery (97–102%). Blanks were routinely analysed for the metals contents and the final results were appropriately corrected. All the measurements were made in triplicate.

2.5. Statistical analysis

The statistical parameters related to the distribution of metals in the cosmetic products were computed using STATISTICA (StatSoft Inc, 1999). Other statistical analyses including correlation and ANOVA were done using SPSS (V13.0), while graphs were plotted through Sigma Plot (V1 2.5) and Bio-Vinci (1.1.5). The analytical data were presented as mean ± SD for triplicate analysis of each sample.

2.6. Health risk assessment

2.6.1. Margin of safety (MoS)

Health risk to humans as a result of exposure to heavy metal impurities present in the cosmetics can be computed in terms of Margin of Safety (MoS), which can be calculated by taking a ratio of No Observed Adverse Effect Level (NOAEL) of the product under study by its systemic exposure dosage (SED) as reported previously (SCCS, 2012).

MoS=NOAELSED (1)

The SED predicts amount of chemicals that enter into human body by various exposure means. It is calculated based on the metal concentration present in the product under study, amount of the product applied per day, frequency of application, surface area of the skin on which the product is applied and average body weight (SCCS, 2012). The SED value was calculated by an expression:

SED(mg/kg/d=Cs×AA×SSA×F×RF×BFBW×10-3 (2)

where, Cs indicates metal concentration in the sample (mg/kg), SSA is the surface area of skin onto which the product is applied (cm2), AA shows the quantity applied (g/cm2), RF is the retention factor, F indicates the application frequency of a product/day, BF is the bioaccessibility factor, 10−3 (mg/kg) is used as unit conversion factor, BW is the average body weight (70 kg) (El-Aziz et al., 2017, SCCS, 2012).

A level of exposure where no adverse effect is observed is called NOAEL and its value was calculated based on dermal reference doses (RfDs) as reported by (USEPA, 2006) using following expression:

NOAEL=RfD×UF×MF (3)

where, UF is uncertainty factor (reflects overall confidence in the various data sets), MF is modifying factor (based on the scientific judgment). Default values for MF and UF are 1 and 100 respectively. RfDs represents dermal reference doses (µg kg−1d−1) of different metals. According to USA risk-based concentration table, dermal reference doses for Cd, Cr, Fe, Ni and Pb are 0.005, 0.015,140, 5.4 and 0.42 µg/kg/d (Achary et al., 2016).

According to World Health Organization (WHO), MoS value up to 100 is acceptable and product with MoS value above 100 is considered safe for use. The scientific committee on consumer’s safety (SCCS) recognizes that in many conventional calculations of MoS, oral bioavailability of an element is assumed to be 100%, if oral absorption data are not available. Standard values of skin surface area (SSA) and amount applied (AA) established by SCCS for cosmetic products are given in Table S2. However, it is considered suitable to assume that not more than 50% of an orally administered dose is systemically accessible (SCCS, 2012).

2.6.2. Hazardous quotient (HQ) and hazard index (HI)

Hazard quotient (HQ) is the ratio of systemic exposure dosage (SED) of a substance to the dermal reference dose (RfD) of each metal (USEPA, 2011, Liu et al., 2013). The HQ value <1 is considered to be safe while the greater than 1 is unsafe for human health. The HQ level was calculated using formula:

HQ=SED/RfD (4)

Hazard index (HI) is the summation of hazard quotients for all the metals under study. It is computed in order to evaluate human health risk due to the exposure of all metallic impurities. The HI value was calculated using following relationship as reported previously (El-Aziz et al., 2017):

HI=HQ=HQCd+HQCr+HQNi+HQFe+HQPd (5)

2.6.3. Lifetime cancer risk (LCR)

Lifetime cancer risk is usually investigated for carcinogenic metals. In the current study, LCR was determined by using following relationship (El-Aziz et al., 2017):

LCR=SED×SF (6)

where, SF represents the carcinogenicity slope factor (mg/kg/d)−1 and it approximates the cancer risk per unit intake dose of an agent to cause cancer over an average lifetime. The reported slope factor for Pb, Cr, Ni and Cd are 0.0085, 0.5, 0.91 and 6.7 (mg/kg/d)−1, respectively (IRIS (Integrated Risk Information System), 2007, USEPA, 2010, WHO, 2008).

3. Results and discussion

3.1. Heavy metals’ distribution in lotions

In total 30 different brands of lotions (n = 90) were analysed and measured levels of HMs were significantly different at p < 0.05 from one brand to another (Table 1). L1 depicted highest level of Cd (2.13 ± 0.15 mg/kg), followed by L19 and L20 (0.27 ± 0.02 and 0.26 ± 0.01 mg/kg, respectively), while in L4 to L11, L22 and L23 brands Cd metal was below the detectable limit. Measured levels of Cd in all samples of lotion were within the permissible limit of 3 mg/kg set by Canadian authority in cosmetic products (HCSC, 2012). Range of Cd observed in the current study was almost comparable as reported earlier by Ababneh and Al-Momani (2018), but was lower than the reported by Borowska and Brzóska (2015). Results showing Cr concentration revealed that in 12 brands of lotions (L4 to L13, L22 and L23), Cr level was below the detection limit. Maximum concentration of Cr was quantified in L20 (0.69 ± 0.02 mg/kg). Comparatively, Cr level was slightly higher in our samples than a previous report (Borowska and Brzóska, 2015). However, Cr was within the safe limit of 50 mg/kg set by USFDA (USFDA, 2013). Generally Fe is considered as essential mineral but its exceeding level may cause serious health issues (Miyajima et al., 2002). In all samples of lotion, measured levels of Fe varied from 0.27 to 7.01 mg/kg. The highest concentration was detected in L24 (7.01 ± 0.14 mg/kg), while lowest was in L23 (0.27 ± 0.19), imported from South Africa.

Table 1.

Measured levels of HMs (mg/kg) in the cosmetic products.

Brand CN SC Cd Cr Fe Ni Pb
Lotions (n = 90)
Nivea Dubai L1 2.1 ± 0.2a 0.08 ± 0.01cdef 2.42 ± 0.38 cd 3.24 ± 0.41b 4.57 ± 0.31d
Mother care Pakistan L2 0.17 ± 0.17bcde 0.42 ± 0.37b 1.72 ± 1.33cdefghi 6.11 ± 0.24a 4.32 ± 0.59de
Vaseline Indonesia L3 0.03 ± 0.02efghij 0.04 ± 0.01cdefg 0.36 ± 0.02hi 1.97 ± 0.07bcde 1.02 ± 0.33jkl
Olivia Pakistan L4 bdl bdl 0.58 ± 0.03fghi 0.83 ± 0.04def 0.77 ± 0.21klm
Care Natural Honey Lotion Pakistan L5 bdl bdl 0.29 ± 0.03i 0.47 ± 0.12ef 1.22 ± 0.25ijk
Jergens Dubai L6 bdl bdl 0.40 ± 0.39hi 2.50 ± 0.38bcd 1.87 ± 0.22hi
Vaseline South Africa L7 bdl bdl 0.27 ± 0.19i 1.19 ± 1.21cdef 1.45 ± 0.16hij
Hollywood Style USA L8 bdl bdl 0.50 ± 0.13ghi 2.27 ± 1.35bcd 1.67 ± 0.03hij
Rivaj UK Pakistan L9 bdl bdl 0.67 ± 0.01efghi 2.33 ± 1.17bcd 1.89 ± 0.20 h
Bath & Body Work USA L10 bdl bdl 0.62 ± 0.10fghi 1.70 ± 0.53bcdef 3.18 ± 0.04 g
Garnier body lotion London L11 bdl bdl 0.38 ± 0.52hi 3.21 ± 0.47b 3.30 ± 0.16 fg
Vaseline dry skin repair South Africa L12 0.01 ± 0.05efghij bdl 0.68 ± 0.08efghi 3.41 ± 0.67b 3.87 ± 0.32ef
Vaseline Olvera Malaysia L13 0.03 ± 0.03efghij bdl 0.58 ± 0.08fghi 1.83 ± 1.16bcde 4.14 ± 0.04de
Remembrance Ireland L14 0.21 ± 0.02bcd 0.59 ± 0.01ab 2.10 ± 0.30cdef 6.15 ± 0.15a 6.97 ± 0.21c
Dove India L15 0.25 ± 0.03bc 0.62 ± 0.04ab 2.71 ± 0.63c 6.24 ± 0.10a 7.19 ± 0.16c
Olay Malaysia L16 0.23 ± 0.04bcd 0.61 ± 0.03ab 1.88 ± 0.57cdefgh 5.95 ± 0.08a 7.30 ± 0.30bc
Enchanteur Dubai L17 0.25 ± 0.04bc 0.66 ± 0.01a 2.23 ± 0.70cde 6.29 ± 0.12a 7.53 ± 0.31bc
Ponds Pakistan L18 bdl 0.01 ± 0.04cdefg 0.89 ± 0.04defghi bdl 0.68 ± 0.08klmn
Johnson's baby lotion Italy L19 0.27 ± 0.02b 0.67 ± 0.03a 2.01 ± 0.72cdefg 6.16 ± 0.33a 7.94 ± 0.10ab
Natural fresh watermelon France L20 0.26 ± 0.01bc 0.69 ± 0.02a 2.42 ± 0.31 cd 6.15 ± 0.13a 8.29 ± 0.09a
Golden pearl lotion Pakistan L21 0.10 ± 0.03cdefghi 0.01 ± 0.02cdefg 0.51 ± 0.09ghi 1.73 ± 0.39bcdef 0.57 ± 0.18klmn
Cream 21 Germany L22 bdl bdl 0.35 ± 0.08hi 2.63 ± 0.19bc 1.071 ± 0.002jkl
Vaseline Petroleum jelly Pakistan L23 bdl bdl 0.34 ± 0.05hi 2.35 ± 0.29bcd 1.49 ± 0.03hij
Salon 7 day protection Pakistan L24 0.17 ± 0.01bcde 0.13 ± 0.01c 7.01 ± 0.14a 0.08 ± 0.01f 0.34 ± 0.02mn
MIEIVIC China L25 0.14 ± 0.02bcdefg 0.12 ± 0.01cde 5.81 ± 0.42ab 0.08 ± 0.04f 0.30 ± 0.02mn
Cream 24 Hour England L26 0.16 ± 0.02bcdef 0.11 ± 0.02cdef 5.64 ± 0.46ab 0.07 ± 0.02f 0.22 ± 0.04mn
Floral Rush Dubai L27 0.07 ± 0.06defghij 0.07 ± 0.02cdefg 4.85 ± 1.34b 0.01 ± 0.05f 0.07 ± 0.17mn
Cucumber Melon USA L28 0.12 ± 0.02bcdefgh 0.08 ± 0.01cdefg 5.20 ± 0.71b 0.05 ± 0.02f 0.26 ± 0.11mn
Glysolid Italy L29 0.14 ± 0.02bcdefg 0.07 ± 0.01cdefg 5.48 ± 0.20ab 0.066 ± 0.004f 0.35 ± 0.06mn
Meijer Moisturizing lotion USA L30 0.15 ± 0.01bcdef 0.12 ± 0.02 cd 5.31 ± 0.35b 0.08 ± 0.02f 0.44 ± 0.05lmn
Max. 2.13 1.00 7.01 6.29 8.29
Min. 0.007 0.008 0.271 0.012 0.068
Mean 0.257 0.283 2.140 2.592 2.809
SE 0.015 0.009 0.070 0.076 0.091
Hair Dyes (n = 18)
Olivia (non-metallic dye) Pakistan D1 bdl bdl 0.27 ± 0.33a 2.5 ± 1.8ab 4.72 ± 0.05d
Revlon Italy D2 0.001 ± 0.021b 0.05 ± 0.02 cd 0.32 ± 018a 3.79 ± 1.00a 5.02 ± 0.15 cd
Garnier Black London D3 bdl 0.08 ± 0.01bc 0.26 ± 0.30a 3.06 ± 0.88a 5.33 ± 0.18bc
Color Pro Greece D4 0.03 ± 0.02b 0.12 ± 0.02ab 0.28 ± 0.27a 3.82 ± 0.27a 5.67 ± 0.23ab
Keune Holland D5 0.03 ± 0.03b 0.13 ± 0.02a 0.42 ± 0.22a 4.17 ± 0.23a 5.84 ± 0.19a
Garnier Dark Brown France D6 0.17 ± 0.02a 0.06 ± 0.02d bdl 0.08 ± 0.02b 0.40 ± 0.11e
Max. 0.169 0.130 0.416 4.167 5.835
Min. 0.001 0.048 0.263 0.081 0.402
Mean 0.057 0.086 0.310 2.900 4.496
SE 0.013 0.006 0.011 0.252 0.341
Foundations (n = 27)
Dermacol Europe F1 0.06 ± 0.03b 0.19 ± 0.03d 45.4 ± 12.0a 4.79 ± 1.33b 3.38 ± 0.26ab
Garner BB Cream Germany F2 0.12 ± 0.03ab 0.23 ± 0.04abcd 5.6 ± 3.3b 5.61 ± 0.38ab 3.56 ± 0.13ab
Cool Beauty Pakistan F3 0.16 ± 0.04a 0.20 ± 0.01 cd 5.3 ± 2.0b 5.46 ± 0.18ab 3.69 ± 0.04ab
Maybelline New York France F4 0.10 ± 0.02ab 0.23 ± 0.01bcd 7.0 ± 4.0b 5.96 ± 0.21ab 3.73 ± 0.20ab
Flormar Perfect Coverage Turkey F5 0.12 ± 0.01ab 0.28 ± 0.02ab 3.0 ± 0.1b 5.83 ± 0.10ab 3.95 ± 0.15a
BB Cream Fair & lovely India F6 0.13 ± 0.01ab 0.19 ± 0.03d 2.3 ± 1.0b 5.66 ± 0.41ab 2.78 ± 2.01ab
Fenty Beauty Italy F7 0.12 ± 0.01ab 0.26 ± 0.01abc 8.3 ± 3.1b 6.34 ± 0.33a 1.94 ± 0.16b
DMGM Secret Wonder Italy F8 0.12 ± 0.02ab 0.26 ± 0.02abc 6.3 ± 1.2b 6.02 ± 0.17ab 2.42 ± 0.06ab
Yardley Foundation London F9 0.06 ± 0.02b 0.30 ± 0.02a 4.0 ± 0.1b 5.49 ± 0.29ab 1.98 ± 0.29ab
Max. 0.157 0.300 45.42 6.336 3.952
Min. 0.059 0.186 2.294 4.788 1.944
Mean 0.109 0.238 9.638 5.684 3.047
SE 0.003 0.004 1.507 0.049 0.087
Whitening creams (n = 18)
Golden Pearl Pakistan W1 0.10 ± 0.03a 0.27 ± 0.01a 1.97 ± 0.44a 6.30 ± 0.21a 2.5 ± 0.2c
Fair & Lovely India W2 0.12 ± 0.04a 0.29 ± 0.01a 2.6 ± 0.2a 5.97 ± 0.55a 3.0 ± 0.2bc
Olay UAE W3 0.12 ± 0.03a 0.32 ± 0.02a 2.2 ± 0.4a 6.29 ± 0.31a 3.1 ± 0.2b
YC Whitening Cream Thailand W4 0.13 ± 0.04a 0.32 ± 0.03a 2.5 ± 0.2a 6.32 ± 0.15a 3.43 ± 0.06ab
Rivaj UK Whitening Cream Pakistan W5 0.13 ± 0.05a 0.29 ± 0.03a 1.80 ± 0.52a 5.94 ± 0.41a 3.44 ± 0.24ab
Stallman’s USA W6 0.14 ± 0.01a 0.30 ± 0.03a 1.86 ± 0.16a 7.0 ± 0.1a 4.0 ± 0.4a
Max. 0.138 0.321 2.598 6.599 4.015
Min. 0.100 0.274 1.799 5.941 2.499
Mean 0.123 0.297 2.154 6.237 3.250
SE 0.002 0.003 0.057 0.041 0.085
Lipsticks (n = 18)
Christine Princess Pakistan LS1 0.15 ± 0.03a 0.32 ± 0.01b 3.0 ± 2.0 cd 6.49 ± 0.14b 4.72 ± 0.17d
Be cute (Velvet sensation) Pakistan LS2 0.19 ± 0.01a 0.33 ± 0.01b 11.0 ± 5.00b 6.48 ± 0.06b 5.02 ± 0.19 cd
KEUNA (MATTE) France LS3 0.2 ± 0.1a 0.46 ± 0.03a 30.0 ± 10.0a 6.59 ± 0.18ab 5.31 ± 0.29bc
Etude Real Australian Australia LS4 0.14 ± 0.04a 0.36 ± 0.01b 11.0 ± 4.00b 6.69 ± 0.22ab 5.59 ± 0.07ab
L’Oreal Paris France LS5 0.20 ± 0.04a 1.0 ± 0.1a 6.1 ± 1.2bc 6.92 ± 0.02a 5.89 ± 0.23a
Toy lipstick China LS6 0.05 ± 0.01b 0.07 ± 0.01c bdl bdl 0.40 ± 0.02e
Max. 0.203 0.465 29.74 6.922 5.889
Min. 0.051 0.074 2.530 6.483 0.404
Mean 0.150 0.335 11.948 6.636 4.488
SE 0.009 0.024 1.753 0.030 0.341
Sunblock (n = 18)
Rivaj Sunblock India S1 0.13 ± 0.02a 0.31 ± 0.03b 2.75 ± 0.32a 7.34 ± 0.86b 6.03 ± 0.25b
Neutrogena (SP525) France S2 0.12 ± 0.02a 0.45 ± 0.02a 2.44 ± 0.39a 6.90 ± 0.19c 6.07 ± 0.16b
Soltan UK S3 0.12 ± 0.03a 0.43 ± 0.02a 2.77 ± 0.45a 6.93 ± 0.12c 6.31 ± 0.05b
Sun care Thailand S4 0.14 ± 0.02a 0.43 ± 0.02a 2.30 ± 0.36a 12.4 ± 0.12a 6.40 ± 0.21ab
Baby ganics sunscreen spray USA S5 0.12 ± 0.01a 0.47 ± 0.03a 2.31 ± 0.28a 7.18 ± 0.48b 6.53 ± 0.27ab
Sunblock (SPF 60) Pakistan S6 0.16 ± 0.01a 0.48 ± 0.02a 2.57 ± 0.37a 7.20 ± 0.15b 6.89 ± 0.04a
Max. 0.155 0.481 2.774 12.37 6.889
Min. 0.121 0.309 2.298 6.900 6.030
Mean 0.132 0.428 2.522 7.989 6.372
SE 0.002 0.010 0.035 0.359 0.053

CN. Country name, SC. Sample code, bdl, below detection limit, Alphabetical letters represents significant differences at p < 0.05.

Concentration of Ni was maximum in L17 (6.29 ± 0.12 mg/kg), whereas lowest level was calculated in L27 (0.01 ± 0.05 mg/kg). However, in L18 Ni was below the detectable limit (Table 1). It was noted that Ni concentration in our samples was comparable with previous reports (Ababneh and Al-Momani, 2018, Borowska and Brzóska, 2015). Recommended level of Ni set by USFDA and Cosmetica Italia is 200 mg/kg (USFDA, 2013) in cosmetics. However, it is suggested that for skin protection Ni and Cr concentration should be <1.0 mg/kg in cosmetic products, particularly that come in direct contact with skin and 0.5 mg/kg of Ni concentration is enough to cause dermatitis (Basketter et al., 2003). Measured level of Pb ranged from 0.07 to 8.29 mg/kg. Highest concentration of Pb was in L20 (8.29 ± 0.09 mg/kg), followed by L19 (7.94 ± 0.10 mg/kg) and L17 (7.53 ± 0.31 mg/kg), while L27 had lowest level (0.07 ± 0.17 mg/kg). Measured levels of Pb in our samples were within regulatory limits set by Canada and USFDA, which are 10 mg/kg and 20 mg/kg, respectively (USFDA, 2013). In addition, range of Pb concentration in lotion samples was almost similar to the previously reported level (Borowska and Brzóska, 2015), but was lower than reported by Ababneh and Al-Momani (2018) in body lotions.

3.2. Heavy metals’ content in hair dye

Measured levels of HMs in 6 brands of hair dyes (n = 18) are presented in Table 1. Comparatively wide variation of Cd was observed among the analyzed samples of hair dye. Wherein, D6 had highest Cd level (0.17 ± 0.02 mg/Kg), which was significantly different from other samples of hair dye (p < 0.05). However, Cd was below the detection limit in D1 and D3. Almost similar Cd concentrations were reported previously (0.01–2.47 mg/kg) by Brzóska et al., 2018, Ozbek and Akman, 2016 in different brands of hair dye. The Cr metal was highest D5 (0.13 ± 0.02 mg/Kg), while in other samples descending order of Cr was: D4 > D3 > D2 > D6. Whereas, in D1 Cr was below the detectable limit. Additionally, measured levels of Cr in our samples were much less than reported earlier (Borowska and Brzóska, 2015, Brzóska et al., 2018). Iron was detected in majority of the samples of hair dye except D6. Highest concentration of Fe was in D5 (0.42 ± 0.22 mg/Kg). Conversely, in D1, D2, D3, D4 and D5 there was no significant difference in Fe concentration (p < 0.05).

Likewise, there was no significant difference in Ni concentration calculated for D2, D3, D4 and D5 samples (3.79 ± 1.00, 3.06 ± 0.88, 3.82 ± 0.27 and 4.18 ± 0.23 mg/Kg, respectively). Whereas, measured level of Ni in D6 (Table 1) was lowest (0.08 ± 0.02 mg/Kg). These values were similar to previous reports in hair dyes (0.03–0.37 mg/Kg) by Ozbek and Akman (2016), but, less than reported by Brzóska et al. (2018). Sample D5 and D4 had highest concentration of Pb at 5.84 ± 0.19 and 5.67 ± 0.23 mg/Kg, respectively, whereas D6 contains least amount of Pb (0.40 ± 0.11 mg/Kg), which was significantly different at p < 0.05 than other brands of hair dyes. In addition, measured levels of Pb in hair dyes were less as compared to previously reported by Brzóska et al. (2018), but were slightly higher than reported by Ozbek and Akman (2016).

3.3. Measure levels of HMs in foundation

In nine different national and international brands (n = 27) of foundation, Cd concentration varied from 0.06 to 0.16 mg/Kg in F9 and F3 samples of foundation respectively (Table 1). In majority of the samples, there was no significant difference in Cd (p < 0.05). Relatively, measured levels of Cd in our samples were lower than reported previously i.e. 0.18–29.1 mg/Kg (Nnorom et al., 2005) and up to 5.09 mg/Kg (Ababneh and Al-Momani, 2018) in the foundation samples collected from the markets of Nigeria and Jordan, respectively. F9 contains highest Cr level (0.30 ± 0.02 mg/Kg), followed by F5, F8 and F7 (0.28 ± 0.02, 0.26 ± 0.02 and 0.26 ± 0.01 mg/Kg, respectively). And these values were comparable with previous report (Borowska and Brzóska, 2015). Fe content in foundation samples depicted wide variation from 45.4 ± 11.7 mg/Kg (F1) to 2.29 ± 1.00 mg/Kg (F6). However, these values were less than reported by Borowska and Brzóska (2015). Ni levels varied from 4.79 to 6.34 mg/Kg in F1 and F7, respectively (p < 0.05). Ni concentration in our samples were comparable with previously reported in foundation (Ababneh and Al-Momani, 2018), but were less than described by Borowska and Brzóska (2015). Concentration of Pb in the analysed samples ranged from 1.94 ± 0.16 to 3.95 ± 0.15 mg/Kg in F7 and F5, respectively (p < 0.05). However, these values were less than previous reports (Ababneh and Al-Momani, 2018, Borowska and Brzóska, 2015).

3.4. HMs’ concentration in whitening cream

Among the different brands of whitening cream (n = 18), comparatively, W6 had highest concentration of Pb (4.02 ± 0.39 mg/Kg), followed by W5 (3.44 ± 0.24 mg/Kg) and W4 (3.43 ± 0.06 mg/Kg). However, these values were not significantly different at p < 0.05 (Table 1). Our findings were almost similar to previously reported levels of Pb in whitening creams from Pakistan (Ullah, 2017), but were much lower than reported in same product by Borowska and Brzóska (2015). No significant differences in the concentration range of Cr (0.27–0.32 mg/Kg), Fe (1.80–2.60 mg/Kg) and Cd (0.10–0.14 mg/Kg) were noted among different brands of whitening cream (p < 0.05). Highest concentration of Cr, Fe and Cd were detected in W4 W2 and W6 respectively (Table 1). Moreover, Cd, Cr and Fe levels in different brands of whitening creams were comparable with previous report (Borowska and Brzóska, 2015), but were relatively less than reported by Ullah (2017).

3.5. Measured levels of HMs’ lipstick

In different brands of lipstick (n = 18), HMs’ concentration vary significantly (p < 0.05) from one brand to another. As shown in Table 1, LS5 depicted highest concentration of Cd (0.20 ± 0.04 mg/Kg), while this metal was lowest in LS6 (0.05 ± 0.01 mg/Kg). Average value of Cd in different brands of lipsticks was comparable to previously reported level (El-Aziz et al., 2017). Cr concentration was ranged from 0.07 to 0.47 mg/Kg, with highest level in LS5 and lowest in LS6. These values were low than reported by El-Aziz et al. (2017), but were comparable to Al-Saleh and Al-Enazi (2011). A wide variation in the concentration of Fe from 2.53 mg/Kg to 29.7 mg/Kg was observed in different brands of lipstick. LS3 had highest Fe content, while it was below the detection limit in LS6. Moreover, Fe levels in our samples were relatively lower than previous reports (El-Aziz et al., 2017;Ullah, 2017). Average concentration of Ni was highest in LS5 (6.92 ± 0.02 mg/Kg), followed by LS4 > LS3 > LS1 > LS2, but were not significantly different at p < 0.05. Additionally, measured levels of Ni were less than reported previously (El-Aziz et al., 2017, Nnorom et al., 2005). Mean concentration of Pb ranged from 0.40 ± 0.02 mg/Kg (LS6) to 5.89 ± 0.23 mg/Kg (LS5) brand. However, measured levels of Pb in our samples were comparable to data provided by Hepp et al. (2009), but were very low than reported by El-Aziz et al. (2017) in different brands of lipstick.

3.6. Distribution of HMs’ sunblock

Average level of Cr in sunblock samples (n = 18) varied from 0.31 to 0.48 mg/Kg, Fe from 2.30 to 2.77 mg/Kg and Cd from 0.12 to 0.16 mg/Kg, with no significant difference (p < 0.05). Highest Cr and Cd contents were detected in S6, while S3 had maximum level of Fe (Table 1). Comparative analysis revealed that measured levels of Fe and Cd were within the range as reported earlier (Ababneh and Al-Momani, 2018, Lim et al., 2018). However, sunblock samples from Korean market contain relatively lower levels of Ni, Pb, Fe, Cr and Cd i.e. 0.07, 0.36, 0.60, 0.12 and 0.002 mg/Kg respectively (Lim et al., 2018). Similarly, lower levels of Pb (0.46 mg/Kg) and Ni (1.77 mg/Kg) were reported by Ababneh and Al-Momani (2018) in Sunblock creams. Ni concentration was maximum in S4, followed by S1, S6 and S5. It was observed that Ni concentration in our samples was relatively higher than reported earlier (Ababneh and Al-Momani, 2018). The highest concentration of Pb was estimated in S6 and lowest was quantified in S1. These values were comparatively higher than previous reports (Ababneh and Al-Momani, 2018).

3.7. Comparative assessment of HMs’ concentration in cosmetic products

Comparative assessment of average heavy metal contents in the cosmetic products is summarized in Table 2. Cadmium exposure leads to several injurious health effects, most prominent are heart failure, kidney, liver and brain damage (Agoramoorthy et al., 2008). In some cases severe eye keratitis had been observed on exposure to high Cd concentration present in kohl (Amry et al., 2011). Average concentration of Cd was ranged from 0.06 ± 0.01 to 0.26 ± 0.02 mg/kg in hair dyes and lotions, respectively. These values were within the safe limit (3 mg/kg) in cosmetic products set by USFDA (2016). Both, Cr (III) and Cr (VI) have potential adverse effects on skin and cause contact allergies and skin cancer (Bocca et al., 2014). Ascending order of mean concentration of Cr in the cosmetic products was: Sunblock > lipstick > whitening cream > lotion > foundation > hair dye. Average concentration of Cr from 0.43 ± 0.01 to 0.09 ± 0.01 mg/kg was lower than the maximum limit (50 mg/kg) set by USFDA (2016). Iron is considered as one of the essential nutrient like Zn, but higher concentration of Fe in cosmetic products causes the death of body cells (Miyajima et al., 2002), thus leads to colorectal cancer (Senesse et al., 2004). In the present study, average concentration of Fe varied from 0.31 ± 0.01 to 12.0 ± 1.75 mg/kg in hair dyes and lipstick, respectively. In other products decreasing order of Fe was: foundation > sunblock > whitening cream > lotion.

Table 2.

Average concentration (±SE) of HMs in cosmetic products.

Cosmetic products No. of samples Cd Cr Fe Ni Pb
Lotion 90 0.26 ± 0.02 0.28 ± 0.01 2.14 ± 0.07 3.0 ± 0.1 2.81 ± 0.09
Hair dyes 18 0.06 ± 0.01 0.09 ± 0.01 0.31 ± 0.01 2.9 ± 0.3 4.50 ± 0.34
Foundations 27 0.115 ± 0.003 0.24 ± 0.004 9.6 ± 1.5 6.0 ± 0.1 3.05 ± 0.09
Whitening creams 18 0.123 ± 0.002 0.297 ± 0.003 2.2 ± 0.1 6.23 ± 0.04 3.25 ± 0.09
Lipsticks 18 0.15 ± 0.01 0.34 ± 0.02 12.0 ± 1.8 6.64 ± 0.03 4.49 ± 0.34
Sunblock 18 0.132 ± 0.002 0.43 ± 0.01 2.52 ± 0.04 8.0 ± 0.4 6.4 ± 0.1

Different brands of sunblock had exceptionally higher Ni concentration, followed by lipsticks, whitening creams, foundations, hair dyes and lotions (Table 2). And exposure to Ni contaminated cosmetics may cause skin allergies (Borowska and Brzóska, 2015). Lead exposure to human body may cause serious health effects including cellular death, DNA damage, and oxidative stress and can also cause neurotoxic, reproductive failure and carcinogenic health effects (Kim et al., 2015). Average concentration of Pb was highest in the sunblock at 6.37 ± 0.05 mg/kg, followed by lipsticks and hair dyes (4.49 ± 0.34 and 4.50 ± 0.34 mg/kg, respectively). The comparative evaluation revealed that on the whole sunblock creams exhibited the highest average concentrations of Cr, Ni and Pb, while Fe and Cd were dominant in the lipsticks and lotions, respectively.

Among different brands of lotions Pb was highest in concentration (2.81 ± 0.09 mg/kg), followed by Ni, Fe, and Cr (2.59 ± 0.08, 2.14 ± 0.07 and 0.28 ± 0.01 mg/kg, respectively), whereas Cd had the lowest value (0.26 ± 0.02 mg/kg) as shown in Fig. 1a. However, none of the analysed metals exceeded their respective permissible limits. The average levels of Pb, Cd and Ni were found to be lower in the present study than the previously reported levels (Ababneh and Al-Momani, 2018, Lim et al., 2018). In the case of hair dyes (Fig. 1b), average Pb content (4.50 ± 0.34 mg/kg) was substantially higher than the other metals, while Cd was at lowest level. Average concentration of Pb in the present study was comparatively higher, while Fe and Cd were comparable to the reported levels (Hussein, 2015) in hair dyes. However, mean Cr content reported in another study (Iwegbue et al., 2016) was much higher in hair dyes while the same samples contained relatively lower level of Ni than the present study. In different brands of foundations (Fig. 1c), Fe was dominating with an average value of 9.64 ± 1.50 mg/kg, followed by and Pb, while Cr and Cd were lowest in concentrations.

Fig. 1.

Fig. 1

(a-f). Average concentration of HMs (mg/Kg) in cosmetic products.

In whitening creams Figure (1d), Ni had highest mean concentration of 6.24 ± 0.04 mg/kg, followed by Pb and Fe (3.25 ± 0.09, 2.15 ± 0.06 mg/kg, respectively), while Cd was relatively lower. Measured levels of Ni were comparatively higher than the previously reported levels in whitening cream from Nigeria, but Cr, Fe and Cd levels were considerably lower than those from Nigeria (Iwegbue et al., 2015, Ababneh and Al-Momani, 2018). In lipsticks, Fe was leading with average concentration of 12.0 ± 1.75 mg/kg (Fig. 1e), followed by Ni and Pb (6.64 ± 0.03 and 4.49 ± 0.34 mg/kg, respectively). These values were within the permissible limits. In addition, mean Pb and Fe concentrations were comparable (Lim et al., 2018), but Cd, Cr and Ni were higher than reported earlier (Ababneh and Al-Momani, 2018, Lim et al., 2018), while, Cd concentration was more or less same as reported by Ababneh and Al-Momani (2018). In the sunblock samples Figure (1f), average concentration of Ni (7.99 ± 0.36 mg/kg) was highest, followed by Pb and Fe (6.37 ± 0.05, 2.52 ± 0.04 mg/kg, respectively), whereas Cd had lowest level (0.132 ± 0.002 mg/kg).

3.8. Multivariate analysis

Different multivariate analysis viz. Pearson’s correlation coefficient, hierarchal cluster analysis (HCA) and principal component analysis (PCA) were performed to identify the natural and anthropogenic sources of HMs’ contamination in cosmetic products. Results of correlation analysis in Table 3, demonstrating there were highly significant (p < 0.01) positive associations between Cr-Pb (r = 0.946), Ni-Pb (r = 0.932) and Cr-Ni (r = 0.916) in different brands of lotion. However, Fe showed negative correlations with all metals. In hair dyes Ni was significantly correlated at p < 0.01 with Pb (r = 0.960), while Cd showed strong negative associations with Ni and Pb (r = −0.972, r = −0.953, respectively) at p < 0.05. In foundation samples there were no significant positive or negative relationships except Fe and Ni (r = −0.702). Pb metal depicted highly significant (p < 0.01), positive interactions with Cd (r = 0.938) in whitening creams and with Cr, Ni and Cd (r = 0.943, r = 0.935 and r = 0.911, respectively) in lipstick samples. Likewise, Pb also had strong positive correlation with Cd and Cr in sunblock samples (Table 3).

Table 3.

correlation coefficient matrixes of HMs’ concentration (mg/Kg) in cosmetic products.

Lotions
Hair Dyes
Variables Cd Cr Fe Ni Pb Variables Cd Cr Fe Ni Pb
Cd 1.000 Cd 1.000
Cr −0.079 1.000 Cr −0.356 1.000
Fe −0.056 −0.319 1.000 Fe 0.209 0.401 1.000
Ni 0.137 0.913** −0.346 1.000 Ni −0.972* 0.547 0.721 1.000
Pb 0.196 0.946** −0.212 0.932** 1.000 Pb −0.953* 0.565 0.535 0.960** 1.000



Foundations Whitening creams

Variables Cd Cr Fe Ni Pb Variables Cd Cr Fe Ni Pb

Cd 1.000 Cd 1.000
Cr −0.263 1.000 Cr 0.403 1.000
Fe −0.539 −0.440 1.000 Fe −0.036 0.367 1.000
Ni 0.405 0.476 −0.702* 1.000 Ni 0.115 0.265 −0.234 1.000
Pb 0.326 −0.409 0.122 −0.321 1.000 Pb 0.938** 0.416 −0.243 0.405 1.000



Lipstick Sunblock

Variables Cd Cr Fe Ni Pb Variables Cd Cr Fe Ni Pb

Cd 1.000 Cd 1.000
Cr 0.887* 1.000 Cr 0.164 1.000
Fe −0.111 0.530 1.000 Fe 0.011 −0.544 1.000
Ni 0.416 0.710 −0.121 1.000 Ni 0.317 −0.003 −0.515 1.000
Pb 0.911* 0.943** 0.113 0.935* 1.000 Pb 0.697 0.696 −0.251 0.060 1.000

** Correlation is significant at the 0.01 level (2-tailed), * Correlation is significant at the 0.05 level (2-tailed).

Hierarchal cluster analysis (HCA) was done using BioVinci 1.15 (Fig. 2). Based on the mean concentration of HMs, different categories of cosmetics products were divided into two main clusters. Foundations and lipstick were in first cluster, whereas whitening creams and sunblock were placed together in second cluster along with close associations of lotions and hair dyes. Color scheme on heat map also compare precisely the HMs concentration in different categories of cosmetic products. Pb and Ni were in same group with highest average concentration in different brands of sunblock, hair dyes, whitening creams and lipstick (Fig. 2). Fe was highest in lipstick and foundation brands, while Cd and Cr were high in different varieties of lotions, lipstick and sunblock.

Fig. 2.

Fig. 2

Hierarchal cluster analysis of HMs in different categories of cosmetic products.

Three principle components viz. PCA1, PCA2 and PCA3 were extracted based on eigenvalue (˃1) and percentage variance more than 81% in PCA analysis executed using Varimex rotation with Kaiser Normalization (Fig. 3). PC1 had 45.15% variation with maximum loading of Ni, Pb and Cr metals with percentage variance of 0.872, 0.842 and 0.789, respectively. The percentage contribution of these metals in PC1 indicating similarity in their sources of contamination. The percentage variation of PC2 and PC3 was 28.87 and 20.34, respectively. Cd metal exhibited highest loading value (0.981) in PC2, while Fe was dominating in PC3 with percentage variance of 0.970 (Table S3).

Fig. 3.

Fig. 3

Principle component analysis of HMs in cosmetic products.

Disparity in HMs concentration among different categories of cosmetic products and their distribution patterns in HCA and PCA is possibly associated with the type of raw material and the sources from where the raw material is collected. For instance, compounds of Fe such as, iron carbonates, ferric hydroxide, iron oxides (iron oxide black, iron oxide red, and iron oxide yellow) and the Cr compounds including Chromium (III) oxide, chromium (III) hydroxide are added intentionally as colour pigments in cosmetic products. Likewise, Cd is used in cosmetics as it has ability to produce different colours when combines with other components (Godt et al., 2006). For instance, the use of cadmium sulphide is because of its yellow colour, also it can develop range of colours from orange to black in combination with increased amount of selenium. Similarly cadmium yellow is added with viridian (Cr (III) oxide) to develop a light green mixture called cadmium green (Bocca et al., 2014). The amount added is dependent on the regulatory limits (EU, 2009), but the same metal may be present an impurity or added intentionally (Bocca et al., 2014). Other metals including Pb, Cd and Ni can be accumulated as impurities at various stages of cosmetic production, predominantly the addition of additives and colour minerals. Moreover, use of solvents, water and different machinery in cosmetic industries during sorting and manufacturing processes may also cause HMs contamination (Łodyga-Chruścińska et al., 2018).

3.9. Health risk assessment

3.9.1. Non-carcinogenic risk

The systemic exposure to cosmetic product predicts the amount of chemicals that enter human body through various exposure routes. The calculated values of systemic exposure dosage (SED) at 50% and 100% bio-accessibility for selected HMs in different cosmetic products are displayed in Table 4. It was noted that at 50% bio-accessibility, SED values for Cd and Cr ranged from 5.85·10−7 to 2.21·10−2 and 1.31·10−6 to 3.22·10−2 mg/kg/d respectively. However, Fe, Ni and Pb lay between 4.67·10−5 to 1.90·10−1, 2.59·10−5 to 6.02·10−1 and 1.75·10−5 to 4.80·10−1 mg/kg/d, respectively. Likewise, SED levels at 100% bio-accessibility for Cd, Cr and Fe ranged from 1.17·10−6 to 4.41·10−2, 2.62·10−6 to 6.44·10−2 and 9.34·10−5 to 3.80·10−1 mg/kg/d, respectively. The respective SED levels of Ni and Pb lay in the range of 5.19·10−5 to 1.20·100 and 3.51·10−5 to 9.60·10−1 mg/kg/d at 100%bio-accessibility. The calculated values of SED were higher than the reported values by El-Aziz et al. (2017) in different facial cosmetic products. In the case of lipsticks, more or less similar SED levels were observed in the previous study (El-Aziz et al., 2017). Additionally, the SED values of HMs in the cosmetic products were almost comparable to those reported by Iwegbue et al. (2016) except for sunblock samples in which comparatively higher levels were recorded in the present study.

Table 4.

SED values (mg/kg/d) of HMs in the cosmetic products.

Sample Cd Cr Fe Ni Pb
50% bio-accessibility
Lotion 2.21·10−2 2.43·10−2 1.84·10−1 2.23·10−1 2.41·10−1
Hair dye 1.15·10−4 2.00·10−4 6.28·10−4 5.89·10−3 9.13·10−3
Foundation 2.25·10−4 4.90·10−4 1.98·10−2 1.17·10−2 6.27·10−3
Whitening cream 1.64·10−3 3.95·10−3 2.86·10−2 8.30·10−2 4.32·10−2
Lipstick 5.85·10−7 1.31·10−6 4.67·10−5 2.59·10−5 1.75·10−5
Sunblock 9.97·10−3 3.22·10−2 1.90·10−1 6.02·10−1 4.80·10−1
100% bio-accessibility
Lotion 4.41·10−2 4.86·10−2 3.67·10−1 4.45·10−1 4.82·10−1
Hair dye 2.31·10−4 2.90·10−4 1.26·10−3 1.18·10−2 1.83·10−2
Foundation 4.50·10−4 9.80·10−4 3.97·10−2 2.34·10−2 1.25·10−2
Whitening cream 3.06·10−3 7.38·10−3 5.35·10−2 1.55·10−1 8.08·10−2
Lipstick 1.17·10−6 2.62·10−6 9.34·10−5 5.19·10−5 3.51·10−5
Sunblock 1.99·10−2 6.44·10−2 3.80·10−1 1.20·100 9.60·10−1

Risk to human health on exposure to metallic impurities present in the cosmetic products was evaluated by applying Margin of Safety (MoS). The estimated levels of MoS for the HMs in the cosmetic products at 50% and 100% bio-accessibility are presented in Table 5. In the samples of hair dye, foundation, whitening cream and lipstick MoS was greater than 100, which revealed that the evaluated samples were safe for use. However, in lotions and sunblock the MoS values for Cd, Cr and Pb were below 100, which indicated that these products are not safe for use, particularly with reference to HMs contamination. In different cosmetic products analyzed by El-Aziz et al., 2017, Iwegbue et al., 2016 levels of MoS were found higher than 100 while MoS for lipsticks was almost similar to the present study.

Table 5.

Margin of Safety (MoS) for selected HMs in the cosmetic products.

Samples Cd Cr Fe Ni Pb
50% bio-accessibility
Lotion 2.27·101 6.18·101 7.62·104 2.43·103 1.74·102
Hair dye 4.33·103 1.03·104 2.23·107 9.17·104 4.60·103
Foundation 2.22·103 3.06·103 7.06·105 4.62·104 6.70·103
Whitening cream 3.05·102 3.80·102 4.89·105 6.51·103 9.72·102
Lipstick 8.55·105 1.15·106 3.00·108 2.08·107 2.39·106
Sunblock 5.01·101 4.66·101 7.37·104 8.97·102 8.75·101
100% bio-accessibility
Lotion 1.13·101 3.09·101 3.81·104 1.21·103 8.71·101
Hair dye 2.17·103 5.17·103 1.11·107 4.59·104 2.30·103
Foundation 1.11·103 1.53·103 3.53·105 2.31·104 3.35·103
Whitening cream 1.63·102 2.03·102 2.61·105 3.48·103 5.20·102
Lipstick 4.27·105 5.73·105 1.50·108 1.04·107 1.20·106
Sunblock 2.51·101 2.33·101 3.69·104 4.49·102 4.38·101

The HQ and HI values of the cosmetic products at 50% and 100% bio-accessibility levels are presented in Fig. 4. At 50% bio-accessibility, HQ values were found relatively higher in the lotion and sunblock samples wherein the values were greater than unity (1) for Cd, Cr and Pb, illustrating threat to human health, while in the samples of hair dye, foundation, whitening cream and lipsticks HQ values were considerably <1 elucidating that the samples were safe for human health.

Fig. 4.

Fig. 4

HQ and HI values of cosmetic products at 50% (A) and 100% (B) bio-accessibility levels.

Similarly, HI levels for the lotion and sunblock were greater than 1 at both 50% and 100% bio-accessibility, which demonstrated that excessive use of these products may cause health risk to consumer. In the case of hair dye, foundation, whitening cream and lipstick, HI levels were much <1, interpreting that the samples were safe for human health. HQ and HI values reported by El-Aziz et al. (2017) were also <1 for different facial cosmetics which are more or less closer to the values obtained in the present study.

3.9.2. Lifetime cancer risk (LCR)

Chromium (Cr), lead (Pb), nickel (Ni) and cadmium (Cd) are listed as carcinogenic HMs by International agency for Research on Cancer (IARC, 2012). Two major routes through which HMs can enter into the body are either by ingestion or through dermal absorption. HMs are non-biodegradable so they remain accumulated into the body for long time period. As a result, they not only alter the cell functions but also cause disruption of intracellular mechanisms (Stavrides, 2006). Therefore, cancer related diseases are enhanced by such impurities that cause oxidative stress, DNA damage and cell death (Kim et al, 2015). Lifetime cancer risk (LCR) is the estimation of potential cancer risk to the users on exposure to HMs present in the cosmetic products. According to USEPA acceptable range for LCR is from 1 × 10–6 to 1 × 10–4 (Loh et al., 2007). The LCR was calculated for cancer causing metals (Pb, Ni, Cr and Cd) at 50% and 100% bio-accessibility (Fig. 5).

Fig. 5.

Fig. 5

LCR of cosmetic products at 50% (A) and 100% (B) bio-accessibility levels.

Among all the analysed HMs, lifetime cancer risk was estimated higher than the permissible limit and the cosmetic products may possess life time cancer risk except lipsticks. Most probable reason is that the lipstick is applied on comparatively small area in relatively less amount. Though, the condition is alarming and continuous use of these products over long time period may cause cancer to the users. It has been reported in previous study that LCR for different facial cosmetic products was below 10−6 including lipstick (Lim et al., 2018).

4. Conclusion

In general, Cr, Ni and Pb were higher in the sunblock samples, while Cd and Fe were maximum in different brands of lotions and lipsticks respectively. Increase in the concentrations of HMs in the cosmetic products was mainly due to the type and source of raw materials used, processing techniques, storage and mode of transportation.

Close association of Cr, Ni and Pd and disparity in Cd and Fe assessed by multivariate analysis revealed similarity and variation in their sources of contamination in cosmetic products. Health risk assessment exposed that generally MoS, HQ and HI values were within the permissible limit for hair dyes, foundations, whitening creams and lipsticks, but were outside the acceptable range for lotions and sunblock creams. The LCR value was higher than the permissible limit in all cosmetic products except lipsticks. Irrespective of the fact that in studied samples HMs concentration were within the regulatory limits, daily exposure to these products may cause cumulative effects such as high risk of skin cancer and other chronic health disorders. Therefore, safer limits for HMs along with their quality control should be obligatory. Additionally, continuous monitoring programmes for the cosmetic products, particularly with reference to HMs adulteration, should be adopted to ensure the human safety and security.

Declarations

Ethics approval and consent to participate

No ethical approval was required to conduct this research work

Consent for publication

Prior consent was taken from all authors to publish findings mentioned in this paper

Availability of data and material

We have already provided all data of research work in this article in tables, figures and supplementary tables

Funding

Data presented here is a part of master student’s research work (first author) and we haven’t funding for this study

Authors’ contribution

HA proposed and conducted research, and prepared first draft, MZ involved in experimental work and data compilation, MHS analyse data and revised article, AMA supervised project, involved in data analysis and finalization of article.

Declaration of Competing Interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Acknowledgements

We are grateful to Department of Chemistry, Quaid-i-Azam University Islamabad and Instrumental labs of COMSATS University Abbottabad campus for providing lab facilities.

Footnotes

Peer review under responsibility of King Saud University.

Appendix A

Supplementary data to this article can be found online at https://doi.org/10.1016/j.jsps.2020.05.006.

Appendix A. Supplementary material

The following are the Supplementary data to this article:

Supplementary data 1
mmc1.docx (16.7KB, docx)

References

  1. Ababneh F.A., Al-Momani I.F. Assessments of toxic heavy metals contamination in cosmetic products. Environ. Forensics. 2018;19(2):134–142. [Google Scholar]
  2. Achary M.S., Panigrahi S., Satpathy K.K., Prabhu R.K., Panigrahy R.C. Health risk assessment and seasonal distribution of dissolved trace metals in surface waters of Kalpakkam, southwest coast of Bay of Bengal. Regional Stud. Mar. Sci. 2016;6:96–108. [Google Scholar]
  3. Agoramoorthy G., Chen F.A., Hsu M.J. Threat of heavy metal pollution in halophytic and mangrove plants of Tamil Nadu, India. Environ. Pollut. 2008;155(2):320–326. doi: 10.1016/j.envpol.2007.11.011. [DOI] [PubMed] [Google Scholar]
  4. Al Amry M., Al-Saikhan F., Ayoubi A. Toxic effect of cadmium found in eyeliner to the eye of a 21 year old Saudi woman: a case report. Saudi Pharm. J. 2011;19(4):269–272. doi: 10.1016/j.jsps.2011.05.002. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Al-Saleh I., Al-Enazi S. Trace metals in lipsticks. Toxicol. Environ. Chem. 2011;93(6):1149–1165. [Google Scholar]
  6. Ayenimo J.G., Yusuf A.M., Adekunle A.S., Makinde O.W. Heavy metal exposure from personal care products. Bull. Environ. Contam. Toxicol. 2010;84(1):8–14. doi: 10.1007/s00128-009-9867-5. [DOI] [PubMed] [Google Scholar]
  7. Barbalova, I. (2011). Global beauty and personal care: the year in review and winning strategies for the future. Cosmetics Milan. (Accessed May 1, 2016).
  8. Basketter D.A., Angelini G., Ingber A., Kern P.S., Menné T. Nickel, chromium and cobalt in consumer products: revisiting safe levels in the new millennium. Contact Dermatitis. 2003;49(1):1–7. doi: 10.1111/j.0105-1873.2003.00149.x. [DOI] [PubMed] [Google Scholar]
  9. Bocca B., Pino A., Alimonti A., Forte G. Toxic metals contained in cosmetics: a status report. Regul. Toxicol. Pharm. 2014;68(3):447–467. doi: 10.1016/j.yrtph.2014.02.003. [DOI] [PubMed] [Google Scholar]
  10. Borowska S., Brzóska M.M. Metals in cosmetics: implications for human health. J. Appl. Toxicol. 2015;35(6):551–572. doi: 10.1002/jat.3129. [DOI] [PubMed] [Google Scholar]
  11. Brzóska M.M., Galażyn-Sidorczuk M., Borowska S. Metal Allergy. Springer; Cham: 2018. Metals in cosmetics; pp. 177–196. [Google Scholar]
  12. Burger P., Landreau A., Azoulay S., Michel T., Fernandez X. Skin whitening cosmetics: Feedback and challenges in the development of natural skin lighteners. Cosmetics. 2016;3(4):36. [Google Scholar]
  13. El-Aziz R.A., Abbassy M.M., Hosny G. Health risk assessment of some heavy metals in cosmetics in common use. Int. J. Environ. Sci. Toxicol. Res. 2017;5(3):53–62. [Google Scholar]
  14. EU, European Union. Regulation (EC) No 1223/2009 of the European Parliament and of the Council of 30 November 2009 on cosmetic products. Official Journal of the European Union L, 342, 22/12/2009, p. 59.
  15. Godt J., Scheidig F., Grosse-Siestrup C., Esche V., Brandenburg P., Reich A., Groneberg D.A. The toxicity of cadmium and resulting hazards for human health. J. Occup. Med. Toxicol. 2006;1(1):22. doi: 10.1186/1745-6673-1-22. [DOI] [PMC free article] [PubMed] [Google Scholar]
  16. HC-SC, 2012 HC-SC (Health Canada-Santé Canada) Guidance on Heavy Metal Impurities In Cosmetics, 2012.
  17. Hepp N.M., Mindak W.R., Cheng J. Determination of total lead in lipstick: development and validation of a microwave-assisted digestion, inductively coupled plasma-mass spectrometric method. J. Cosmet. Sci. 2009;60(4):405. [PubMed] [Google Scholar]
  18. Hussein H.J. Evaluation of the concentration of some heavy metals in hair dyes in Baghdad. Int. J. Sci. Res. 2015;4:687–691. [Google Scholar]
  19. IARC monographs on the evaluation of carcinogenic risk to human. Volume 100C. Lyon, International Agency for Research on Cancer, 2012.
  20. Iavicoli I., Fontana L., Bergamaschi A. The effects of metals as endocrine disruptors. J. Toxicol. Environ. Health, Part B. 2009;12(3):206–223. doi: 10.1080/10937400902902062. [DOI] [PubMed] [Google Scholar]
  21. IRIS (Integrated Risk Information System). 2007. Chromium. Integrated Risk Information System, DC: U.S. Environmental Protection Agency, Place, Published Report, 1170Number.
  22. Iwegbue C.M., Bassey F.I., Tesi G.O., Onyeloni S.O., Obi G., Martincigh B.S. Safety evaluation of metal exposure from commonly used moisturizing and skin-lightening creams in Nigeria. Regul. Toxicol. Pharm. 2015;71(3):484–490. doi: 10.1016/j.yrtph.2015.01.015. [DOI] [PubMed] [Google Scholar]
  23. Iwegbue C.M., Onyeloni S.O., Bassey F.I., Tesi G.O., Ogboru R.O., Martincigh B.S. Safety evaluation of metal exposure from commonly used hair dyes and tattoo inks in Nigeria. J. Environ. Health. 2016;78(6):26. [PubMed] [Google Scholar]
  24. Kim H.S., Kim Y.J., Seo Y.R. An overview of carcinogenic heavy metal: molecular toxicity mechanism and prevention. J. Cancer Prevention. 2015;20(4):232. doi: 10.15430/JCP.2015.20.4.232. [DOI] [PMC free article] [PubMed] [Google Scholar]
  25. Li G., Schoneker D., Ulman K.L., Sturm J.J., Thackery L.M., Kauffman J.F. Elemental impurities in pharmaceutical excipients. J. Pharm. Sci. 2015;104(12):4197–4206. doi: 10.1002/jps.24650. [DOI] [PubMed] [Google Scholar]
  26. Lim D.S., Roh T.H., Kim M.K., Kwon Y.C., Choi S.M., Kwack S.J., Lee B.M. Non-cancer, cancer, and dermal sensitization risk assessment of heavy metals in cosmetics. J. Toxicol. Environ. Health, Part A. 2018;81(11):432–452. doi: 10.1080/15287394.2018.1451191. [DOI] [PubMed] [Google Scholar]
  27. Liu S., Hammond S.K., Rojas-Cheatham A. Concentrations and potential health risks of metals in lip products. Environ. Health Perspect. 2013;121(6):705. doi: 10.1289/ehp.1205518. [DOI] [PMC free article] [PubMed] [Google Scholar]
  28. Locatelli C., Melucci D., Locatelli M. Toxic metals in herbal medicines. A review. Curr. Bioactive Compd. 2014;10(3):181–188. [Google Scholar]
  29. Locatelli M., Furton K.G., Tartaglia A., Sperandio E., Ulusoy H.I., Kabir A. An FPSE-HPLC-PDA method for rapid determination of solar UV filters in human whole blood, plasma and urine. J. Chromatogr. B. 2019;1118:40–50. doi: 10.1016/j.jchromb.2019.04.028. [DOI] [PubMed] [Google Scholar]
  30. Łodyga-Chruścińska E., Sykuła A., Więdłocha M. Hidden metals in several brands of lipstick and face powder present on polish market. Cosmetics. 2018;5(4):57. [Google Scholar]
  31. Loh M.M., Levy J.I., Spengler J.D., Houseman E.A., Bennett D.H. Ranking cancer risks of organic hazardous air pollutants in the United States. Environ. Health Perspect. 2007;115(8):1160–1168. doi: 10.1289/ehp.9884. [DOI] [PMC free article] [PubMed] [Google Scholar]
  32. Miyajima H., Kono S., Takahashi Y., Sugimoto M. Increased lipid peroxidation and mitochondrial dysfunction in aceruloplasminemia brains. Blood Cells Mol. Dis. 2002;29(3):433–438. doi: 10.1006/bcmd.2002.0561. [DOI] [PubMed] [Google Scholar]
  33. Nnorom I.C., Igwe J.C., Oji-Nnorom C.G. Trace metal contents of facial (make-up) cosmetics commonly used in Nigeria. Afr. J. Biotechnol. 2005;4(10) [Google Scholar]
  34. Nohynek G.J., Antignac E., Re T., Toutain H. Safety assessment of personal care products/cosmetics and their ingredients. Toxicol. Appl. Pharmacol. 2010;243(2):239–259. doi: 10.1016/j.taap.2009.12.001. [DOI] [PubMed] [Google Scholar]
  35. OJEU, Official Journal of the European Union, 2009. Regulation (EC) No 1223/2009 of the European Parliament and of the Council of 30 November 2009 on cosmetic products, pp. 59–208.
  36. Olmedo P., Pla A., Hernández A.F., López-Guarnido O., Rodrigo L., Gil F. Validation of a method to quantify chromium, cadmium, manganese, nickel and lead in human whole blood, urine, saliva and hair samples by electro thermal atomic absorption spectrometry. Anal. Chim. Acta. 2010;659(1–2):60–67. doi: 10.1016/j.aca.2009.11.056. [DOI] [PubMed] [Google Scholar]
  37. Ozbek N., Akman S. Determination of lead, cadmium and nickel in hennas and other hair dyes sold in Turkey. Regul. Toxicol. Pharm. 2016;79:49–53. doi: 10.1016/j.yrtph.2016.05.013. [DOI] [PubMed] [Google Scholar]
  38. Saeed M., Muhammad N., Khan H. Assessment of heavy metal content of branded Pakistani herbal products. Trop. J. Pharm. Res. 2011;10(4):499–506. [Google Scholar]
  39. SCCS, 2012. The Scientific Committee on Consumer Safety: notes of guidance for the testing of cosmetic substances and their safety evaluation–8th revision. SCCS/1501/12.
  40. Senesse P., Méance S., Cottet V., Faivre J., Boutron-Ruault M.C. High dietary iron and copper and risk of colorectal cancer: a case-control study in Burgundy, France. Nutr. Cancer. 2004;49(1):66–71. doi: 10.1207/s15327914nc4901_9. [DOI] [PubMed] [Google Scholar]
  41. Smith, V., Clark, S., Wilkinson, M., 2015. Allergic contact dermatitis in children: trends in allergens, 10 years on. A retrospective study of 500 children tested between 2005 and 2014 in one Ukcentre: p23 (pp11). Br. J. Dermatol., 173, 31. [DOI] [PubMed]
  42. Stavrides J.C. Lung carcinogenesis: pivotal role of metals in tobacco smoke. Free Radical Biol. Med. 2006;41(7):1017–1030. doi: 10.1016/j.freeradbiomed.2006.06.024. [DOI] [PubMed] [Google Scholar]
  43. Tartaglia A., Kabir A., Ulusoy S., Sperandio E., Piccolantonio S., Ulusoy H.I., Locatelli M. FPSE-HPLC-PDA analysis of seven paraben residues in human whole blood, plasma, and urine. J. Chromatogr. B. 2019;1125 doi: 10.1016/j.jchromb.2019.06.034. 121707. [DOI] [PubMed] [Google Scholar]
  44. Ullah H., Noreen S., Rehman A., Waseem A., Zubair S., Adnan M., Ahmad I. Comparative study of heavy metals content in cosmetic products of different countries marketed in Khyber Pakhtunkhwa, Pakistan. Arabian J. Chem. 2017;10(1):10–18. [Google Scholar]
  45. USEPA, 2006. ENERGY STAR Overview of 2006 Achievements. US Environmental Protection Agency. Climate Protection Partnerships Division, Washington, DC. March 1.
  46. USEPA, 2010. Toxicology review of hexavalent chromium.
  47. USEPA . USA, US; Environmental Protection Agency, Washington, DC: 2011. Regional Screening Level Table (RSL) for Chemical Contaminants at Superfund Sites. [Google Scholar]
  48. USFDA, 2013. Drug Safety Communication. Important Safety Label Changes to Cholesterol-Lowering Statin Drugs.
  49. USFDA, 2016. FDA approves folic acid fortification of corn masa flour. https://www.fda.gov/news-events/press-announcements.
  50. WHO, 2008. The Scientific Basis of Tobacco Product Regulation: second report of a WHO Study Group. WHO Technical Report Series, No.951. Switzerland.

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary data 1
mmc1.docx (16.7KB, docx)

Data Availability Statement

We have already provided all data of research work in this article in tables, figures and supplementary tables


Articles from Saudi Pharmaceutical Journal : SPJ are provided here courtesy of Elsevier

RESOURCES