Skip to main content
. 2020 May 7;219(7):e201907098. doi: 10.1083/jcb.201907098

Table 1. Data collection and refinement statistics.

Parameters (Data collection statistics) SeMet OPA1-MGD
Data collection statistics
Cell parameters
a (Å) 77.9
b (Å) 77.9
c (Å) 171.5
α, β, γ (°) 90.0, 90.0, 90.0
Space group P43212
Wavelength used (Å) 0.9798
Resolution (Å) 50.0–2.40 (2.49-2.40)c
No. of all reflections 472,513 (19,636)
No. of unique reflections 21,509 (2,067)
Completeness (%) 99.9 (98.9)
Average I/σ(I) 20.56 (1.52)
Rmergea (%) 14.4(98.1)
Refinement statistics
No. of reflections used (σ(F) > 0) 19,817
Rworkb (%) 21.2
Rfreeb (%) 25.9
r.m.s.d. bond distance (Å) 0.01
r.m.s.d. bond angle (°) 1.408
Average B-value (Å2) 34.7
No. of protein atoms 2,559
No. of ligand atoms 35
No. of solvent atoms 143
Ramachandran plot
res. in favored regions (%) 94.5
res. in allowed regions (%) 5.4
res. in outlier regions (%) 0.1
a

Rmerge = ΣhΣl | Iih-Ih |/ΣhΣIIh where Ih is the mean of observations Iih of reflection h.

b

Rwork = Σ(||Fp(obs)|-|Fp(calc)||)/Σ|Fp(obs)|. Rfree is an R factor for a pre-selected subset (5%) of reflections that was excluded in the refinement.

c

Numbers in parentheses are corresponding values for the highest resolution shell.