Table 1.
Behavioral face-detection results (Experiment 2): percent accuracy (A), response time (RT; B), and inverse efficiency (IE; C). One standard error for each measurement is given in parentheses.
| Frequency (Hz) | 120 | 60 | 40 | 30 | 24 | 20 | 12 | 6 | 3 |
|---|---|---|---|---|---|---|---|---|---|
| A. Accuracy (%) | −0.4 (0.49) | 3.0 (1.26) | 21.7 (3.17) | 42.9 (5.59) | 57.9 (5.20) | 68.0 (4.32) | 95.6 (2.12) | 97.8 (0.86) | 98.0 (1.01) |
| B. RT (ms) | 1435 (145) | 650 (52.7) | 557 (19.2) | 529 (18.9) | 505 (11.0) | 503 (15.2) | 498 (13.4) | 495 (15.3) | 499 (15.2) |
| C. IE | 84.7 (260) | 74.5 (20.8) | 32.0 (4.85) | 14.2 (1.91) | 10.1 (1.16) | 8.11 (0.81) | 4.29 (0.26) | 5.07 (0.18) | 5.11 (0.18) |