Heating and Cooling System |
Air source heat pump |
Supplemental Dehumidification |
Whole-house dehumidifier, 50 % RH setpoint |
Temperature Control Scheme |
Fixed setpoints in heating mode (21 °C [70 °F]) and cooling mode (24 °C [75 °F]); More user-configurable wall-mounted thermostat |
Ventilation |
Heat recovery ventilator |
Ventilation Control Scheme |
Intermittent: 43 minutes on during each hour, average airflow rate of 140 m3/h (80 cfm) |
Water Heating System |
Solar preheat with heat pump water heater backup – Two tank system |
Water Fixtures Used |
Master bath shower, master bath tub, master bath sink, 2nd floor bath shower, 2nd floor bath sink, kitchen sink |
Simulated Occupancy |
Two adults, two children |
Rated Photovoltaic Output |
10.24 kW |
Start Date |
February 1, 2015 |
End Date |
January 31, 2016 |