Skip to main content
. 2016 Oct 7;121:436–463. doi: 10.6028/jres.121.023

Table 2.

Measurement Uncertainties of NIST Disciplined Clocks (all values are in nanoseconds)

Uncertainty Component Best Case (independent antenna survey, intracontinental baseline) Worst Case (self-survey of antenna, intercontinental baseline)
UAN, Time Transfer Noise 2 2
UBA, Antenna Coordinates 1 25
UBC, Calibration 5 5
UBE, Environment 3 3
UBI, Ionospheric Delay 1 3
UBM, Multipath 2 2
UBD, Reference Delay 0.5 0.5
UBR, Resolution 0.05 0.05
UC, k = 2 13.3 52.0