Table 2.
Complementary hemodynamic parameters for norepinephrine data traces in Fig. 5
Stressor (Corresponding Part of Fig. 5) | LVSP (Baseline, Stimulated), mmHg | LV Developed Pressure (Baseline, Stimulated), mmMg/s |
---|---|---|
Aortic occlusion (A) | 115, 156 | 1,733, 1,655 |
IVC occlusion (B) | 106, 72 | 1,850, 1,044 |
PVC stimulation (C) | 133, 152 | 1,584, 1,787 |
Left ventricular (LV) peak systolic pressure (LVSP; mmHg) and developed LV pressure (dP/dt, mmHg/s) were measured before and during (baseline, stimulated) indicated stressors simultaneously with the fast-scanning cyclic voltammetry recordings presented in the indicated corresponding part of Fig. 5. IVC, inferior vena cava; PVC, premature ventricular contraction.