Skip to main content
. 2020 Jun 5;9(6):446. doi: 10.3390/pathogens9060446

Table 3.

Mean Legionella concentration in relation to ranges of temperature measured (I, II, III, and IV).

Range of Temperature
(°C)
Number of Samples Number of Positive Samples
(%)
Mean Legionella Concentration
(Log cfu/L)
95% Confidence Interval
(CI)
Range of Temperature Comparison ANOVA
Test
p-Value
(p)
I <21 168 54
(32.1)
1.78 1.65–1.91 vs. II 0.464
vs. III 0.002*
vs. IV 1.000
II 21–45 157 59
(37.6)
1.98 1.81–2.15 vs. I 0.464
vs. III 0.474
vs. IV 0.012 *
III 45.1–49.6 172 81
(47.1)
2.17 2.00–2.34 vs. I 0.002 *
vs. II 0.474
vs. IV 0.001 *
IV >49.6 172 40
(23.2)
1.64 1.51–1.78 vs. I 1.000
vs. II 0.012 *
vs. III 0.001 *

* Values are statistically significant at p ≤ 0.05.