Skip to main content
. 2020 Jul 12;187(8):441. doi: 10.1007/s00604-020-04415-3

Table 2.

Selection of various graphene-modified impedimetric sensors to quantify proteins and disease-relevant biomarkers

Material Modification Analyte Linear Range LOD Selectivity Reference
rGO MWCNT-Au NPs-chitosan Lysozyme 0.02–250 pM 9 fM BSA, HSA, Hb, thrombin, IgG, CytC, PSA, enzymes [123]
rGO MWCNT-Au NPs PSA 5–0.1 μg mL−1 1 pg mL−1 BSA, Hb, thrombin, IgG, lysozyme [124]
rGO SWCNT-Au NPs-aptamer HER2 0.1 pg mL−1 - 1 ng mL−1 50 fg·mL−1 BSA, BHb, thrombin, IgG, lysozyme, PSA [125]
cvdG Anti-OVA Ovalbumin 1–0.1 pg mL−1 0.9 pg mL−1 β-LG, lysozyme [88]
cvdG Anti-CEA CEA 1.0–25.0 ng mL−1 0.23 ng mL−1 KCl, CYFRA-21-1, CTnI [83]
cvdG Anti-IgG IgG 0.1–100 μg mL−1 0.136 μg mL−1 BSA, Hb, avidin [78]

BSA bovine serum albumin, CEA carcinoembryonic antigen, (MW/SW)CNT multi-walled/single-walled carbon nanotubes, CRP c reactive protein, CTnI cardiac troponin I, CytC cytochrome C, (B)Hb (bovine) hemoglobin, HER2 human epidermal growth factor, HSA human serum albumin, β-LG β-lactoglobulin, Mb myoglobin, PSA prostate-specific antigen