Table 3. Laboratory test and allergy test results in patients with EoE and controls.

Laboratory test and allergy test EoE patients Controls p-value
Serum eosinophil count (/mm3) 344.0 (238.0–500.0) 127.5 (88.8–181.8) 0.01
Serum eosinophil ≥500/mm3 6 (28.6) 0 (0.0) <0.001*
Total 21 42
Serum IgE count (U/mL) 383.0 (212.0–618.5) 60.5 (37.5–330.0) 0.04
Serum IgE ≥100 U/mL 10 (90.9) 6 (42.9) 0.03*
Total 11 14
Negative allergy tests 2 (11.8) 10 (52.6) 0.01
Positive allergy tests 15 (88.2) 9 (47.4)
Total 17 19

Values are presented as median (interquartile range), number (%), or number only.

EoE: eosinophilic esophagitis, Ig: immunoglobulin.

*p-value from Fisher's exact test. Allergy tests included IgE-specific blood tests or skin allergy prick tests.