Table 3. Apnea testing in countries in Asia and the Pacific.

Examination component Number of protocols (n=24)
Preparation for testing
 Check for spontaneous breathing before conducting apnea testing 2 (8)
 Complete the clinical examination for the determination of BD/DNC before conducting apnea testing 9 (38)
 Obtain an arterial blood gas reading before apnea testing 13 (54)
 Review the PaCO2 value before apnea testing
  PaCO2 should be normal 1 (8)
  PaCO2 should be 35–45 mm Hg 7 (54)
  PaCO2 should be ~40 mm Hg 1 (8)
  PaCO2 should be ≥40 mm Hg 3 (23)
  PaCO2 should be 40–45 mm Hg 1 (8)
 Review the pH value before apnea testing
  Target not stated 12 (92)
  pH should be normal 1 (8)
 Factors that may preclude apnea testing
  Not stated 22 (92)
  High-level spinal cord injury 1 (4)
  Hypoxia 1 (4)
 Preoxygenation
  Not stated 5 (21)
  5 min of FiO2=100% 1 (4)
  10 min of FiO2=100% 15 (63)
  15 min of FiO2=100% 1 (4)
  PaO2 ≥200 mm Hg 5 (21)
  Decrease respiratory rate by 2 breaths/min and increase FiO2 to 100% 1 (4)
Apnea testing procedure
 Not stated 3 (13)
 Not described in detail 2 (8)
 Administer oxygen (amount not specified) 1 (4)
 Administer oxygen at 4–6 L/min 2 (8)
 Administer oxygen at 6 L/min 11 (46)
 Administer oxygen at 6–8 L/min 1 (4)
 Administer oxygen at 10 L/min 1 (4)
 Disconnect the ventilator 16 (67)
 Place a catheter above the carina 8 (33)
 Place a catheter 1 cm beyond the endotracheal tube 1 (4)
 Turn off backup ventilation if testing is done on the ventilator 1 (4)
 Utilize CPAP 3 (13)
 Utilize a T-piece 5 (21)
Reasons to end apnea testing
 Not stated 9 (38)
 8 min has passed 2 (8)
 10 min has passed 6 (25)
 Dysrhythmia 7 (29)
 Hemodynamic disturbance 3 (13)
 Hypotension (general) 3 (13)
 Hypotension with SBP <90 mm Hg 5 (21)
 Hypoxia (general) 3 (13)
 Hypoxia with saturation <85% 4 (17)
 Hypoxia with saturation <90% 1 (4)
 Hypoxia with saturation <91% 1 (4)
 Spontaneous breathing 10 (42)
Target value of apnea testing
 Not stated 5 (21)
 PaCO2 ≥50 mm Hg 2 (8)
 PaCO2 ≥55 mm Hg 1 (4)
 PaCO2 >60 mm Hg 4 (17)
 PaCO2 ≥60 mm Hg 12 (50)
 PaCO2 increase of 10–15 mm Hg above baseline 1 (4)
 PaCO2 increase of ≥20 mm Hg above baseline 12 (50)
 pH target provided 0 (0)
Next steps if apnea testing is aborted and no breaths were seen but the PaCO2 target value was not reached
 Not stated 13 (54)
 Perform an ancillary test 9 (38)
 Perform a blood flow 2 (8)
 Repeat the test after 3 hours 1 (4)
 Repeat the test with CPAP 2 (8)
 Repeat the test for longer 1 (4)
 Repeat the test with a higher oxygen flow rate 2 (8)

Data are n (%).

BD/DNC: brain death/death by neurologic criteria, CPAP: continuous positive airway pressure, SBP: systolic blood pressure.