Table 3.
Target pollutants and instrumentation/sampling methods.
| Pollutant | Instrument/method(s) | Duration |
|---|---|---|
| Total PM | Modified U.S. EPA Method 5 (EPA, n.d.-a) | Integrated run, 0–4 h |
| PCDDs/PCDFs | U.S. EPA Method 23 (EPA, 1991)/HRGC-HRMS | Integrated run, 0–4 h |
| PAHs | U.S. EPA Method 0010 (EPA, 1986)/HRGC-LRMS | Integrated run, 0–4 h |
| VOCs | SUMMA Canister/U.S. EPA Method TO-15 (EPA, 1999c), including CO2, CO, CH4/U.S. EPA Method 25C (EPA, n.d.-f) | Integrated run, ∼2 h |
| NOx, O2, CO, CO2 SO2, CH4, HCl | FTIR - Gasmet DX-4000 (Finland) | Real time |
| CO2 | LI-COR 820 (Biosciences, USA) | Real time |
| Metal: Mercury | Sorbent trap/U.S. EPA Method 30B (EPA, n.d.-b) | Integrated run, 0–4 h |
| Metals: Cd, Pb, others | Teflon filters/Modified U.S. EPA Method 5 (EPA)/gravimetric and X-Ray Fluorescence (XRF) (EPA, 1999a) and/or Inductively coupled plasma (ICP) (EPA, 1999b) | Integrated run, 0–4 h |