Table 1. Initial values and upper and lower boundary fitting to Eq. [1].
Fitting parameters | Amy | Aax | Aex | (ms) | (ms) | (ms) | fmy (Hz) | fax (Hz) | fex (Hz) | φ0 |
---|---|---|---|---|---|---|---|---|---|---|
Initial value | 0.1|S1| | 0.6|S1| | 0.3|S1| | 10 | 64 | 48 | 5 | 0 | 0 | ∠|S1| |
Lower bound | 0 | 0 | 0 | 3 | 24 | 24 | −75 | −25 | −25 | −ð |
Upper bound | 2|S1| | 2|S1| | 2|S1| | 24 | 1,000 | 1,000 | 75 | 25 | 25 | ð |
S1 is the complex signal of the first echo.