Electrocardiographic findings of the study population

  Control TAVI group (n = 101) Complete heart block‐TAVI (+) (n = 49) p Value
Heart rate (bpm) 73.6 ± 8.9 87.1 ± 8.6 <.001
Tp‐e (ms) 59.2 ± 6.1 74.2 ± 5.1 <.001
QTmin (ms) 349.0 ± 3.8 349.3 ± 3.9 .669
QTmax (ms) 374.8 ± 5.4 374.7 ± 5.6 .912
QTc (ms) 368.1 ± 7.8 397.6 ± 3.4 <.001
JT (ms) 286.0 ± 4.4 286.1 ± 4.4 .874
JTc (ms) 291.1 ± 6.7 317.4 ± 11.3 <.001
Tp‐e/QT 0.20 ± 0.04 0.28 ± 0.04 <.001
Tp‐e/QTc 0.19 ± 0.03 0.29 ± 0.04 <.001
Tp‐e/JT 0.23 ± 0.03 0.32 ± 0.03 <.001
Tp‐e/JTc 0.22 ± 0.03 0.30 ± 0.02 <.001
QTd (ms) 17.8 ± 3.6 34.4 ± 3.0 <.001
QRS (ms) 85.9 ± 3.8 85.8 ± 3.9 .943

JT interval (JT) was measured from the end of the QRS complex (J point) to the end of the T wave (JT end interval); QT dispersion (QTd) was determined as the difference between the maximum and minimum QT interval.