Table 2.

Mean (± standard deviation) peak hemodynamic parameters calculated from respiratory- and cardiac-gated 4D Flow MRI in healthy volunteers and single ventricle patients. P-values represent the difference between healthy subjects and single ventricle patients.

Parameter Units Healthy Volunteer (Maximum) Single Ventricle (Maximum) P-value
Flow ml/cycle 322 ± 96 272 ± 106 0.132
Flow Index (Flow/Stroke Volume) 1/cycle 4.32 ± 0.85 3.24 ± 1.36 0.027
Ventricle KE (Systole) mJ 3.16 ± 1.60 5.02 ± 2.28 0.049
Ventricle KE (Diastole) mJ 3.72 ± 2.01 4.52 ± 4.20 0.38
Efficiency Index (KE/Flow) ml/cycle/mJ 140 ± 64 71 ± 52 0.02
Vorticity rad/s 0.26 ± 0.23 0.57 ± 0.24 0.212
Reynolds Number - 5401 ± 2177 5454 ± 2222 0.478
Aorta Relative Area Change % 46 45 0.5
SVC Relative Area Change % 65 36 0.004
IVC Relative Area Change % 41 66 0.125
IVC KE mJ 6.98 3.2 0.021
SVC KE mJ 3.34 1.44 0.0004