Skip to main content
. 2020 Jul 14;7:48. doi: 10.1186/s40658-020-00317-8

Table 2.

Quantitative dataset characteristics. (a) Top row reports the number of VOIHEALTHY and related volume value (mean and standard deviation) for both pre- and post-treatment dataset, and the middle row refers to VOITUMOR; while the bottom row illustrates the data related to VOILUNGS with volumes values after the shrinkage process for both 166Ho-only and 166Ho-DI. b) median and quartile deviation of mean absorbed dose recovered in VOIs, for both 166Ho-only and 166Ho-DI are reported. First row refers to VOIHEALTHY, second to VOITUMOR, and third to VOILUNGS, respectively

(a) Pre-treatment Post-treatment
VOI Number Volume Number Volume
Healthy 26 27.57 ml 32 27.57 ml
Tumor 21 27.50 ml ± 3.91 23 26.27 ml ± 2.23
Lungs 26

2399.30 ml ± 971.77 (166Ho-Only)

2182.47 ml ± 794.58 (166Ho-DI)

31

2578.09 ml ± 1026.67 (166Ho-Only)

2263.47 ml ± 841.22 (166Ho-DI)

(b) 166Ho-only 166Ho-DI
VOI Median Quartile deviation (IQR/2) Median Quartile deviation (IQR/2)
Healthy 27.12 Gy 7.08 Gy 26.22 Gy 8.00 Gy
Tumor 116.27 Gy 44.91 Gy 108.96 Gy 46.00 Gy
Lungs 2.99 Gy 0.99 Gy 3.88 Gy 1.07 Gy