Skip to main content
. 2020 Jun 9;12(6):1319. doi: 10.3390/polym12061319

Table 5.

Measurement results of investigated samples.

Sample Code Mass per Unit Area *, g/m2 Thickness D *, mm Air Permeability *, mm/s Thermal Resistance Rct *, m2K/W Heat Transfer Coefficient U, W/m2K Thermal Conductivity Coefficient λ, W/m K
C 372 ± 5 2.7 ± 0.1 618 ± 15 0.063 ± 0.009 15.87 0.043
C1 557 ± 8 2.6 ± 0.1 414 ± 30 0.072 ± 0.010 13.89 0.036
C2 401 ± 6 2.6 ± 0.1 636 ± 15 0.064 ± 0.009 15.62 0.041
C3 375 ± 5 2.7 ± 0.1 641 ± 28 0.065 ± 0.009 15.34 0.042
C4 375 ± 5 2.7 ± 0.1 629 ± 17 0.068 ± 0.010 14.71 0.040

Notes: * The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor k = 2, which provides a level of confidence of approximately 95%; U, λ values are presented without uncertainty as they were estimated from Rct and D measurements.