TABLE 1.
List of parameters used by operations in the Segmentation stage of our motivating application and their range values. The search space formed is of about 21 trillion points
| Parameter | Description | Range values |
|---|---|---|
| B/G/R | Background detection thresholds | [210, 220, …, 240] |
| T1/T2 | Red blood cell thresholds | [2.5, 3.0, …, 7.5] |
| G1 | Thresholds to identify candidate nuclei | [5, 10, …, 80] |
| G2 | Thresholds to identify candidate nuclei | [2, 4, …, 40] |
| MinSize (minS) | Candidate nuclei area threshold | [2, 4, …, 40] |
| MaxSize (maxS) | Candidate nuclei area threshold | [900, …, 1500] |
| MinSizePl(minSPL) | Area threshold before watershed | [5, 10, …, 80] |
| MinSizeSeg (maxSS) | Area threshold in final output | [2, 4, …, 40] |
| MaxSizeSeg (minSS) | Area threshold in final output | [900, …, 1500] |
| FillHoles (FH) | Propagation neighborhood | [4-conn, 8-conn] |
| MorphRecon (RC) | Propagation neighborhood | [4-conn, 8-conn] |
| Watershed (WConn) | Propagation neighborhood | [4-conn, 8-conn] |