. 2020 Jul 14;6(7):e04459. doi: 10.1016/j.heliyon.2020.e04459

Table 8.

SIC optimization solution using the PSO algorithm.

S-CO2 – RORC – Cyclohexane
S-CO2 – SORC – Cyclohexane
Base case Optimized Absolute difference [%] Base case Optimized Absolute difference [%]
TIT [°C] 750 800 6.66 750 800 6.66
PHIGH [MPa] 25 30 20 25 30 20
TC [°C] 65 67.67 2.10 65 66.06 2.46
rP 15 30 100 15 30 100
W˙net,ORC [kW] 27.46 36.31 32.19 23.65 29.68 25.54
W˙net,SCO2ORC[kW] 122.75 148.73 21.16 118.93 142.11 19.49
ηI, ORC [%] 14.95 21.07 40.93 14.93 17.23 15.40
ηI,overall [%] 49.01 52.76 7.65 47.48 50.41 6.17
Δηth [%] 28.82 32.30 12.07 24.81 26.40 6.40
BSFCBraytonSCO2ORC [g/kWh] 153.02 188.05 22.89 157.93 188.05 19.07
ΔBSFC [%] 22.37 24.41 9.11 19.88 20.89 5.13
LCOE [USD/kWh] 0.26 0.22 15.38 0.24 0.22 8.33
PBP [year] 11.17 9.89 11.45 10.76 9.63 10.50
SIC [USD/kWh] 2613.13 2308.91 11.64 2515.67 2248.17 10.63