Ultraviolet germicidal irradiation (UVGI) interventions and N95 filtering facemask respirators used to evaluate UVGI decontamination on viral or bacterial load

Author and year Wavelength (nm) Watts (W) Duration (min)a Dose (J/m2) Intensity (mW/cm2) Distance (cm)b UVGI study arms N95 masks evaluated
Fisher, 2010c NR 40 1–300 1500–5000 2.5 NR Model A-1: 10 min, 15000 J/m2
Model C 1: 1 min, 1500 J/m2
Model C-2: 2 min, 3000 J/m2
Model C-3: 4 min, 6000 J/m2
Model C-4: 10 min, 15,000 J/m2
Model F 1: 1 min, 1500 J/m2
Model F-2: 2 min, 3000 J/m2
Model F-3: 4 min, 6000 J/m2
Model F-4: 10 min, 15,000 J/m2
Cardinal N95-ML (A)
3M 8210 (C)
3M 1870 (F)
Heimbuch, 2011d 254 80 15 18,000 1.6–2.2 25 Single UVGI arm 3M 8000
3M 8210
Moldex 1500
3M 1860
3M 1870
Kimberly Clark PFR
Lin, 2018e 254 6 1–20 11,340 to 226,800 18.9 10 Arm 1: UVC 245 nm, 1 min, 11,340 J/m2
Arm 2: UVC 245 nm, 2 min, 22,680 J/m2
Arm 3: UVC 245 nm, 5 min, 45,360 J/m2
Arm 4: UVC 245 nm, 10 min, 113,400 J/m2
Arm 5: UVC 245 nm, 20 min, 226,800 J/m2
3M 8210
Lore, 2012 254 15 15 18,000 1.6–2.2 25 Single UVGI arm 3M 1860
3M 1870
Mills, 2018 254 NR 1 1000 0.39 100 cm Single UVGI arm 3M 1860
3M 1870
3M VFlex 1805
Alpha Protech 695
Gerson 1730 Cup
Kimberly-ClarkPFR
Moldex 1512 Cup
Moldex 1712 Flat-fold
Moldex
EZ-22
Precept
65–3395
Prestige Ameritech RP88020
Sperian HC-NB095
Sperian HC-NB295F
U.S. Safety AD2N95A
U.S. Safety AD4N95
Vo, 2009 254 40 60–300 14,400–72,000 0.4 NR Arm 1: 1 hr (14,400 J/m2)
Arm 2: 2 hr (28,800 J/m2)
Arm 3: 3 hr (43,200 J/m2)
Arm 4: 4 hr (57,600 J/m2)
Arm 5: 5 hr (72,000 J/m2)
N1105
Woo, 2012 254 4 15–120 9,000–72,000 1.0 10 Arm 1: 15 min, 9,000 J/m2
Arm 2: 30 min, 18,000 J/m2
Arm 3: 60 min, 36,000 J/m2
Arm 4: 120 min, 72,000 J/m2
3M 1870

NR, not reported.

a

Refers to the duration for which the N95 filtering facemask respirator (FFR) models were exposed to ultraviolet.

b

Refers to the distance from the ultraviolet light to the N95 FFR model(s).

c

Fisher et al. evaluated 22 different UVGI protocols and six different masks, however, germicidal results were only reported for nine arms and three masks.

d

Mask models for the following studies obtained through private correspondence: Heimbuch (2011).

e

Lin et al. also evaluated five UVGI arms using 365-nm ultraviolet-A light.