Table IV.
Ultraviolet germicidal irradiation (UVGI) interventions and N95 filtering facemask respirators used to evaluate UVGI decontamination on viral or bacterial load
| Author and year | Wavelength (nm) | Watts (W) | Duration (min)a | Dose (J/m2) | Intensity (mW/cm2) | Distance (cm)b | UVGI study arms | N95 masks evaluated |
|---|---|---|---|---|---|---|---|---|
| Fisher, 2010c | NR | 40 | 1–300 | 1500–5000 | 2.5 | NR | Model A-1: 10 min, 15000 J/m2 Model C 1: 1 min, 1500 J/m2 Model C-2: 2 min, 3000 J/m2 Model C-3: 4 min, 6000 J/m2 Model C-4: 10 min, 15,000 J/m2 Model F 1: 1 min, 1500 J/m2 Model F-2: 2 min, 3000 J/m2 Model F-3: 4 min, 6000 J/m2 Model F-4: 10 min, 15,000 J/m2 |
Cardinal N95-ML (A) 3M 8210 (C) 3M 1870 (F) |
| Heimbuch, 2011d | 254 | 80 | 15 | 18,000 | 1.6–2.2 | 25 | Single UVGI arm | 3M 8000 3M 8210 Moldex 1500 3M 1860 3M 1870 Kimberly Clark PFR |
| Lin, 2018e | 254 | 6 | 1–20 | 11,340 to 226,800 | 18.9 | 10 | Arm 1: UVC 245 nm, 1 min, 11,340 J/m2 Arm 2: UVC 245 nm, 2 min, 22,680 J/m2 Arm 3: UVC 245 nm, 5 min, 45,360 J/m2 Arm 4: UVC 245 nm, 10 min, 113,400 J/m2 Arm 5: UVC 245 nm, 20 min, 226,800 J/m2 |
3M 8210 |
| Lore, 2012 | 254 | 15 | 15 | 18,000 | 1.6–2.2 | 25 | Single UVGI arm | 3M 1860 3M 1870 |
| Mills, 2018 | 254 | NR | 1 | 1000 | 0.39 | 100 cm | Single UVGI arm | 3M 1860 3M 1870 3M VFlex 1805 Alpha Protech 695 Gerson 1730 Cup Kimberly-ClarkPFR Moldex 1512 Cup Moldex 1712 Flat-fold Moldex EZ-22 Precept 65–3395 Prestige Ameritech RP88020 Sperian HC-NB095 Sperian HC-NB295F U.S. Safety AD2N95A U.S. Safety AD4N95 |
| Vo, 2009 | 254 | 40 | 60–300 | 14,400–72,000 | 0.4 | NR | Arm 1: 1 hr (14,400 J/m2) Arm 2: 2 hr (28,800 J/m2) Arm 3: 3 hr (43,200 J/m2) Arm 4: 4 hr (57,600 J/m2) Arm 5: 5 hr (72,000 J/m2) |
N1105 |
| Woo, 2012 | 254 | 4 | 15–120 | 9,000–72,000 | 1.0 | 10 | Arm 1: 15 min, 9,000 J/m2 Arm 2: 30 min, 18,000 J/m2 Arm 3: 60 min, 36,000 J/m2 Arm 4: 120 min, 72,000 J/m2 |
3M 1870 |
NR, not reported.
Refers to the duration for which the N95 filtering facemask respirator (FFR) models were exposed to ultraviolet.
Refers to the distance from the ultraviolet light to the N95 FFR model(s).
Fisher et al. evaluated 22 different UVGI protocols and six different masks, however, germicidal results were only reported for nine arms and three masks.
Mask models for the following studies obtained through private correspondence: Heimbuch (2011).
Lin et al. also evaluated five UVGI arms using 365-nm ultraviolet-A light.